Hoshizaki KML-200MWE, KML-200MAE Removal and Replacement of HOT GAS Valve and Line Valve

Page 37

4)Remove the insulation and the Expansion Valve Bulb on the suction line.

5)Remove the Expansion Valve Cover, and disconnect the Expansion Valve using brazing equipment.

6)Braze the new Expansion Valve, with nitrogen gas flowing at the pressure of 3 - 4 PSIG.

WARNING

Always protect the valve body by using a damp cloth to prevent the valve from overheating. Do not braze with the valve body exceeding 250°F.

7)Install the new Drier.

8)Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

9)See the Nameplate for the required refrigerant charge.

10)Attach the Bulb to the suction line in position. Be sure to secure it with clamps and to insulate it.

11)Place the new set of Expansion Valve Covers in position.

12)Replace the panels in their correct positions.

13)Turn on the power supply.

6.REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVE

CAUTION

Always use a copper tube of the same diameter and length when replacing the hot gas lines; otherwise the performance may be reduced.

37

Image 37
Contents KML-200MAE KML-200MWE Foreword Contents Refrigerant Recovery Evacuation and Recharge Specifications 1. KML-200MAE KML-200MWE KML-200MAE II. General Information ConstructionKML-200MWE SOLID-STATE Control Controller BoardController Board Page Alpine C/Alpine Board Important Water Valve opening is limited to 6 minutes Sequence 1st Cycle2nd Cycle and after with pump drain Line Valve2nd Cycle and after with no pump drain OFF KML-200MWE Controls and Adjustments Alpine/Alpine C BoardSetting Time Setting Frequency Checking Controller Board Test Program of Controller Board Control Switch SwitchesService Switch III. Technical Information KML-200MWE KML-200MAE, KML-200MWE Wiring DiagramsIf Float Sw. is OFF Timing ChartTo Freeze Cycle From Freeze Cycle Performance Data Heat of Rejection from Condenser Problem Possible Cause Remedy IV. Service Diagnosis No ICE ProductionController Board Clean LOW ICE Production Evaporator is Frozen UPOthers Abnormal ICEEvacuation and Recharge Refrigerant RecoveryBrazing Removal and Replacement of Compressor ImportantPage Removal and Replacement of Expansion Valve Removal and Replacement of DrierRemoval and Replacement of HOT GAS Valve and Line Valve Page Removal and Replacement of Evaporator Important Page Adjustment of Water Regulating Valve WATER-COOLED Model only Removal and Replacement of Thermistor Caution Removal and Replacement of FAN Motor Removal and Replacement of Pump Motor Removal and Replacement of Water ValveRemoval and Replacement of Spray Tube Page Page Cleaning Page Sanitizing Procedure Following Cleaning Procedure Maintenance

KML-200MWE, KML-200MAE specifications

The Hoshizaki KML-200MWE and KML-200MAE are commercial ice machines renowned for their high performance and reliability in the foodservice industry. Both models are designed to meet the needs of businesses that require a consistent supply of ice for various applications, including restaurants, bars, and hotels.

One of the standout features of the KML-200MWE and KML-200MAE is their ability to produce high volumes of crisp, clear ice. These machines utilize a combination of advanced refrigeration technology and a unique ice-making process that ensures a rapid ice production rate while maintaining energy efficiency. The modular design allows for easy integration into existing setups, making them an ideal choice for operators looking to expand their ice supply without a complete equipment overhaul.

The KML-200MWE features a built-in water-cooled condenser, allowing for operation in environments where air-cooled systems may not be viable. This feature is particularly useful in warm climates or kitchens with limited ventilation, as it ensures that the machine operates efficiently, regardless of external temperatures. In contrast, the KML-200MAE incorporates an air-cooled condenser, making it a more flexible option for operators who prioritize energy savings and ease of maintenance.

Both models utilize a unique fluorinated refrigerant, which not only enhances their cooling efficiency but also aligns with modern environmental standards. The internal components are constructed from high-quality stainless steel, ensuring durability and resistance to corrosion. Moreover, their easy-to-access design simplifies maintenance routines, enabling operators to keep the machines running smoothly with minimal downtime.

Another key feature of the KML-200MWE and KML-200MAE is their ice storage capacity. With an ample bin size, these machines can store a significant amount of ice, reducing the need for frequent refills and making them ideal for busy establishments. Additionally, they are equipped with automatic ice level controls, which help maintain optimal ice quantities while preventing overflow.

Hoshizaki ice machines are also recognized for their innovative air filtration systems, which improve the quality of the ice produced. This ensures that the ice is not only abundant but also free from any contaminants, meeting the high standards of hygiene expected in the food industry.

In summary, the Hoshizaki KML-200MWE and KML-200MAE are exemplary models that blend technology, efficiency, and durability. Their advanced features make them suitable for various commercial applications, providing operators with reliable performance and peace of mind. Whether choosing the water-cooled or air-cooled variant, businesses can expect a high-quality product that enhances their ice production capabilities.