Jackson aj-86ce, AJ-86CGP, AJ-64CS, AJ-64CE, AJ-86CS, AJ-100CS, AJ-100CGP Equipment Mounting, Plumbing

Page 44

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

D226 STEAM BOOSTER INSTALLATION & OPERATION INSTRUCTIONS

CONCEALED DAMAGE OR MISSING PARTS:

IMPORTANT: FOR YOUR PROTECTION, PLEASE READ AND OBSERVE THE FOLLOWING:

This steam booster has been thoroughly inspected and carefully packed before leaving our warehouse.

Concealed loss or damage means loss or damage which does not become apparent until the booster has been unpacked. The contents may be damaged in transit due to rough handling even though the carton may not show external damage.

If it is found that the shipment has concealed damage, PLEASE DO NOT RETURN IT TO JACKSON, but notify the carrier (within 48 hours) asking them to send their agent to fill out an inspection report. Save the cartons so he may inspect them and be sure to note in the report any black marks, creases, tears, crushed corners or any other marks indicating rough handling. Also, notify your JACKSON dealer immediately.

If it is discovered that there are missing parts, please notify your JACKSON dealer immediately.

EQUIPMENT MOUNTING:

Your booster should come pre-assembled and will require that it be permanently mounted in place. The platform has pre- punched holes to allow for mounting to the installation floor. NOTE: The D226 Booster must be properly mounted and level before being used. Once the platform is secure to the floor, attach the water and steam lines in accordance with local and national codes.

PLUMBING:

NOTE: ALL CONNECTIONS MUST COMPLY WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL PLUMBING CODES.

The plumber is responsible for ensuring that the water line is THOROUGHLY FLUSHED BEFORE connecting it to any manu- al or solenoid valve. It is necessary to remove all foreign matter such as chips (resulting from cutting or threading pipes), pipe joint compound or, if soldered fittings are used, bits of solder or cuttings from the lines. This debris, if not removed, may lodge in the valves and render them inoperative.

The D226 Booster is designed to take incoming water from a minimum temperature of 110°F to approximately 180°F for use in the final rinse of your Jackson dishmachine. In order to do this, water is supplied to the booster and is heated by tubes carry- ing 15-25 PSIG flow steam. Heat is transferred from the steam into the water, raising the temperature.

Install condensate drains in accordance with applicable codes.

The D226 Booster is designed to operate at a water flow rate of 20 ±5 PSI. The assembly comes with a water pressure reg- ulator, which is preset at the factory. However, adjustment may be required so ensure that you verify the the flow pressure before beginning operations. See the instructions regarding adjustment and maintenance of the water pressure regulator for more information.

WARNING: The D226 Booster is designed to heat water to a minimum of 180°F and is extremely hot during operations. Advise personnel of the dangers associated with touching booster components as burns or severe injury can occur.

This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components. Use of deion- ized water or other aggressive fluids will void the manufacturer's warranty.

AJ-64 Conveyor Series Technical Manual 7610-003-30-93

Issued: 05-02-2006 Revised: N/A

36

Image 44
Contents For Jackson Models AJ-86CGPManufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN AJ-64CS Nomenclature for the Models Covered in this ManualTable of Contents D226 Steam Booster Section Parts Parts SectionSide Loader Section Electrical Schematics VII Viii Maintenance & Repair CentersSection Specification Information Specification Information AJ-64CE Models AJ-86CE ModelsAJ-64CS Models AJ-86CGP ModelsAJ-100CE Models AJ-100CGP ModelsAJ-100CS Models D226 Steam BoosterSpecification Information AJ-64 Electric Left to Right Left to RightSpecification Information AJ-64 Electric Right to Left Right to LeftSpecification Information AJ-64 GAS Left to Right Left to RightRight to Left Information to LeftRight InformationAJ-64 Steam Left to Specification Information AJ-64 Steam Right to Left Right to LeftSpecification Information Electric Left to Right AJ-86Right to Left Specification Information AJ-86 GAS Left to Right Recommended Table FabricationAJ-86 GAS Right to LeftLeft to Right AJ-86 Steam Left toSpecification Information AJ-86 Steam Right to Left Specification Information AJ-100 Electric Left to Right Left to RightTo Left Section Right to Left AJ-100 GAS Right toLeft to Right AJ-100 Steam Left toSpecification Information AJ-100 Steam Right to Left Right to LeftSide Loader Left to Right Dimensions Section A-ASide Loader Right to Left Dimensions 2 DRAIN. Connected to Dishmachine Drain LineLeft to Right installation shown for reference Side Loader Installation Dimensions Side Loader DimensionsD226 Steam Booster Dimensions D226 Steam Booster Plumbing Line Drawings Typical Electric and GAS Booster Dimensions Rear ViewSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installation InstructionsIncoming Power Connection Brass Plug Detergent Connection Point Machine rear view Deliming Operations Placement of the curtains Please refer to the chart for Side Loader Installation & Operation Instructions Equipment Mounting PlumbingShutdown for Service only OperationGAS Conveyor Hose Installation Conveyor Hose Installation GASDishmachine Operating Instructions Dishmachine Operation Instructions Detergent Control Striker Plate Limit Switch Installation Instructions Installation InstructionsSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceD226 Maintenance Maintenance of the Water Pressure RegulatorLubrication Chart for Drive Gear SHC-90WDrive Motor Gear Reducer Preventative Maintenance Lubrication & MaintenanceSection Troubleshooting Section Troubleshooting Common ProblemsTorque Settings Items Torque SpecD226 Troubleshooting Section Problem Power light does not illuminate

AJ-100CE, AJ-100CGP, AJ-100CS, aj-86ce, AJ-86CS specifications

The Jackson AJ series of guitars exemplifies a dedication to high-quality craftsmanship, innovative technology, and stunning aesthetics, making them a favorite among guitarists of various skill levels.

The AJ-100CGP is a standout model in the lineup, featuring a solid spruce top and mahogany back and sides that deliver a rich and vibrant tone. This guitar embodies a classic dreadnought design, offering a full, powerful sound ideal for both strumming and fingerpicking. Its high-gloss finish enhances its visual appeal while also promising durability, making it suitable for regular performances and practice sessions. The inclusion of a rosewood fretboard provides smooth playability and features elegant dot inlays for easy navigation along the neck.

The AJ-86CS offers a slightly different aesthetic with its cutaway design, allowing for improved access to higher frets, making it a great choice for lead guitarists. It combines a solid cedar top with mahogany back and sides, creating a warm and articulate tone, perfect for a range of musical styles from folk to rock. The fishman pickup system integrated into this model ensures that the guitar sounds incredible both plugged and unplugged, allowing musicians to connect in various performance settings.

For those seeking an elegant option, the AJ-100CE is an acoustic-electric guitar that pairs a solid spruce top with mahogany back and sides as well. The onboard electronics maintain the guitar's natural voice, providing an authentic acoustic sound when amplified. The cutaway body shape not only adds visual flair but also enhances playability, making it a preferred choice for solo performances.

The AJ-64CS showcases vintage tones with its solid Sitka spruce top paired with carefully selected mahogany back and sides. This guitar is designed with a classic vibe, featuring detailed binding and a distressed finish that evokes a sense of nostalgia. The AJ-64CS is favored by players who appreciate well-balanced sound and sustainable construction.

Lastly, the AJ-86CE brings a high-performance focus to the lineup with its innovative features. Similar to the AJ-100CE, it boasts a cutaway design and an enhanced pickup system for amplified clarity. The blend of spruce and mahogany offers intricate tonal possibilities, catering to both strumming and intricate fingerstyle techniques.

In conclusion, each model in the Jackson AJ series presents unique characteristics and sound profiles, marrying classic craftsmanship with modern technology. This makes them versatile instruments suited for a wide range of musical expressions, making them invaluable additions to any guitarist’s arsenal.