York YCWS manual REF no

Page 35

FORM 201.24-EG1

REF NO

YCWS0100

YCWS0120

YCWS0140

YCWS0180

YCWS0200

YCWS0220

YCWS0240

 

A

3527

3527

3527

4775

4775

4775

4775

 

 

 

 

 

 

 

 

 

 

B

1715

1715

1715

2316

2316

2316

2316

 

 

 

 

 

 

 

 

 

 

C

953

953

953

1556

1556

1556

1556

 

 

 

 

 

 

 

 

 

 

D

1524

1524

1524

1524

1524

1524

1524

 

 

 

 

 

 

 

 

 

 

E

905

905

905

994

994

994

994

 

 

 

 

 

 

 

 

 

 

F

1459

1459

1459

2069

2069

2069

2069

 

 

 

 

 

 

 

 

 

 

G

1459

1459

1459

2069

2069

2069

2069

 

 

 

 

 

 

 

 

 

 

H

1169

1169

1169

1722

1722

1722

1722

 

 

 

 

 

 

 

 

 

 

I

1169

1169

1169

1722

1722

1722

1722

 

 

 

 

 

 

 

 

 

 

J

156

156

156

130

130

130

130

 

 

 

 

 

 

 

 

 

 

K

210

210

210

229

229

229

229

 

 

 

 

 

 

 

 

 

 

L

210

210

210

251

251

251

251

 

 

 

 

 

 

 

 

 

 

M

1829

1893

1893

2010

2010

2010

2010

 

 

 

 

 

 

 

 

 

 

N

1033

1033

1033

1085

1085

1085

1085

 

 

 

 

 

 

 

 

 

 

O

601

601

601

613

613

613

613

 

 

 

 

 

 

 

 

 

 

P

254

254

254

254

254

254

254

 

 

 

 

 

 

 

 

 

 

Q

708

708

708

837

837

837

837

 

 

 

 

 

 

 

 

 

 

R

1038

1038

1038

1038

1038

1038

1038

 

 

 

 

 

 

 

 

 

 

S

864

864

864

914

914

914

914

 

 

 

 

 

 

 

 

 

 

T

432

432

432

457

457

457

457

 

 

 

 

 

 

 

 

 

 

U

406

406

406

422

422

422

422

 

 

 

 

 

 

 

 

 

 

V

127

127

127

152

152

152

152

 

 

 

 

 

 

 

 

 

 

W

203

203

203

203

203

203

203

 

 

 

 

 

 

 

 

 

 

X

337

337

337

362

362

362

362

 

 

 

 

 

 

 

 

 

 

 

 

REVISED DIMENSIONS FOR 200/230V CHILLERS

 

 

 

 

 

 

 

 

 

 

 

 

REF

YCWS0100

YCWS0120

YCWS0140

YCWS0180

YCWS0200

YCWS0220

YCWS0240

 

C

819

819

819

1422

1422

1422

1422

 

D

1791

1791

1791

1791

1791

1791

1791

 

Q

530

530

530

659

659

659

659

 

R

1219

1219

1219

1219

1219

1219

1219

 

NOTES:

1. CLEARANCES - Recommended YORK clearances to service the unit are as follows:

Rear to Wall:

508mm

Front to Wall:

813mm

Top:

508mm

Tube cleaning and removal:

2438mm (either end)

2. Shipping skids (not shown) will increase the height of the unit by 152mm, but MUST be removed upon installation.

3. Spring and neoprene isolators will increase the over- all height of the unit by approximately 76mm.

YORK INTERNATIONAL

35

Image 35
Contents Ycws Nomenclature York Ycws Water Cooled Screw Chillers IntroductionSpecifications Microprocessor Controls Program Electrical Options Multiple Point Power Supply Connection Accessories & OptionsYcws Design ParametersTEV Cooler Water Pressure Drop Curves English Pressure DropsCooler Water Pressure Drop Curves SI Cond Fouling Factors Selection DataGuide to Selection Selection RulesSample Selection SolutionRatings R-22 English Leaving Condenser Water Temperature FYCWS0200SC Ratings R-22 SI Leaving Condenser Water Temperature CYCWS0200SC Ratings- Brine 30 % Ethylene Glycol R-22 English 85.0 Ratings- Brine 30 % Ethylene Glycol R-22 SI 30.0 Ratings- Brine 30 % Propylene Glycol R-22 English YCWS0200SC Ratings- Brine 30 % Propylene Glycol R-22 SI YCWS0200SC Part Load Ratings COP English Physical DataModel Isolator Selection DataIsolator Mounting Bracket Isolator DetailsIsolator Details English Sound Data Dimensions English Dimensions Mounting Dimensions mm REF no LRA Electrical DataSystem #1 Chiller Volt MIN NF MAX Dual Code CIR Disc SW Fuse RLA ModelSystem #2 Chiller Volt Single Point Power Supply see & 11 , page 30 Single Point Power Supply Incoming Wire Range SelectionsMultipoint Wiring System #1 Multipoint Wiring System #2 Multipoint Power Supply Connection Standard Unit Customer Wiring DataVoltage Code Typical Control Panel Wiring Form 201.24-EG1 Application Data Refrigerant Circuits Guide SpecificationsCompressors Capacity Control SystemMicrocomputer Control Center Power PanelForm 201.24-EG1 York International Form 201.24-EG1 Form 201.24-EG1 RPC 3M 701 New Release Codes DXS, ET

YCWS specifications

York YCWS, or York Chilled Water System, represents a revolutionary approach to modern commercial cooling solutions, offering efficiency, reliability, and sustainability. Designed specifically for large-scale applications such as industrial facilities, data centers, and office buildings, the York YCWS aims to optimize energy use while maintaining climatic comfort indoors.

One of the standout features of the York YCWS is its advanced chiller technology. Utilizing cutting-edge centrifugal chillers, the system maximizes cooling through a combination of high efficiency and low operational costs. These chillers operate with variable speed drives, allowing them to adjust their output based on the real-time cooling demand. This leads to significant energy savings, especially in fluctuating load conditions, and reduces wear on the equipment, extending its lifespan.

The YCWS also incorporates smart control systems that enhance its overall performance. These controls employ algorithms to anticipate system demands, dynamically balancing the load across multiple chillers and optimizing energy use throughout the day. Integration with building management systems (BMS) allows for seamless communication and remote monitoring, giving facility managers greater oversight and control over their cooling operations.

Sustainability is at the core of the York YCWS design. The system uses environmentally friendly refrigerants that comply with global standards for reducing greenhouse gas emissions. Additionally, the modular design of the chiller units allows for easy upgrades and expansions, accommodating growing cooling needs without necessitating a complete system overhaul. This flexibility supports a more energy-efficient and environmentally responsible operational model.

The system's footprint is relatively compact, allowing it to fit into tighter spaces typically found in urban settings. Furthermore, the YCWS is engineered for quiet operation, minimizing noise disturbances for occupants in and around the building.

Reliability is another key characteristic of the York YCWS. With a focus on durability and performance, these systems are built to function optimally in various environmental conditions. The robust construction and high-quality materials ensure long-term service, reducing the need for frequent maintenance and associated costs.

In summary, the York YCWS is not just a cooling solution but a comprehensive system that embodies modern engineering principles. Its efficiency, sustainability, and adaptability make it a preferred choice for industries looking to invest in their future. With its smart technologies and robust features, the York Chilled Water System is well-equipped to meet the demanding needs of today's commercial cooling challenges.