Keating Of Chicago 37399 user manual Avoid Service Checklist, Warranty Repairs, Parts Ordering

Page 9

PREVENTIVE MAINTENANCE CLEANING

CHART

 

TIME

OPERATOR/OWNER

 

 

FRAME

 

 

 

At Least

Clean MIRACLEAN® Griddle surface.

 

 

Daily

Drain and clean grease drawer.

 

 

 

Completely wipe down MIRACLEAN®

 

 

 

Griddle cabinet.

 

 

At Least

Check MIRACLEAN® Griddle surface

 

 

Monthly*

to insure proper maintenance.

 

 

 

(Review proper cooking procedures.)

 

 

 

Check calibration of thermostats.

 

 

 

Review operating instructions

 

 

 

received with MIRACLEAN® griddle.

 

 

Every

Clean gas valve vent tube.

 

 

6 Months*

Check burner manifold pressure.

 

 

At Least

QUALIFIED SERVICE PERSONNEL ONLY

 

 

Yearly*

Have MIRACLEAN® griddle completely

 

 

 

checked, calibrated, tested, cleaned, etc.

 

 

 

by qualified service personnel. Be sure to

 

 

 

check color and height of pilot flame.

 

 

 

 

 

*High production facilities should be checked more often. Contact the factory or a local service company to perform maintenance and repairs.

AVOID SERVICE CHECKLIST

Before calling for service, review this list. It may save you both time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

 

PROBLEM

 

SOLUTION

 

 

 

 

 

Miraclean® Griddle

 

• Is the gas connected?

 

 

does not operate:

 

• Is the gas supply turned on?

 

 

 

 

• Is the gas valve knob in the ON

 

 

 

 

position?

 

 

 

 

• Is the pilot lit?

 

 

 

 

• Is the switch turned on?

 

 

 

 

• Is the thermostat set at the desired

 

 

 

 

position?

 

 

 

 

 

 

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. In the event that your Miraclean® Griddle, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800 KEATING).

THERMOSTAT CALIBRATION

Calibration is not covered under warranty.

Tools: Accurate surface thermometer

Standard screwdriver

1.Turn the exhaust system ON.

2.Turn on the griddle with thermostat set at 300°F. Allow burners to cycle on and off three times. (Approximately 60 minutes.)

3.Place accurate thermometer on surface over thermostat bulb. Use the inverted “V” on the front of the griddle plate to locate thermostat bulb. Place the surface thermometer about half waytoward the back of the plate.

4.When burners cycle off, the griddle is up to temperature. If temperature is within 25°F of thermostat setting, remove knob. Loosen four screws in the thermostat dial plate. Replace knob. Reset the dial plate to match the thermometer reading.

Thermostat calibration

Thermostat knob removed to reveal calibration screws.

5.Remove the knob to tighten screws on dial plate and replace the knob.

For calibration over a 50°F difference, contact a qualified service company.

DO NOT ADJUST THE THERMOSTAT SET SCREW - IT VOIDS ANY WARRANTY ON PART

CONDITIONING THE

MIRACLEAN® GRIDDLE PLATE

The Miraclean® Griddle plate has been “seasoned” at the factory. The Miraclean® surface when heated creates a thin layer of chrome oxide which acts as a releasing agent for food product. You may feel that you need to recondition your griddle surface.

1.Follow cleaning instructions on page 5.

2.Heat the MIRACLEAN® to 400°F for one hour.

3.Lower thermostat to 350°F, allowing the MIRACLEAN® to cool to about 350°F, as is evident when griddle cycles on or surface thermometer indicates correct temperature.

4.Lightly coat the MIRACLEAN® surface with griddle oil.

NOTE: Despite the food releasing properties, the chrome surface is not a true “non-stick” surface. For best cooking results and product appearance, use griddle oil for products that require the surface to be conditioned.

PARTS ORDERING

Parts may be ordered by part number by calling Keating at 1- 800-KEATING or your service company. You may also order on-line at Keating’s part store, www.keatingofchicago.com.

Refer to the Keating MIRACLEAN® Griddle Limited Warranty for complete service and ordering information.

The model/serial plate is located inside the cabinet. Remove grease drawer. The model and serial numbers are necessary when ordering.

7

Image 9
Contents Contents Miraclean GAS Griddle SeriesFor Your Safety Introduction Installation InstructionsIf Equipment Arrives Damaged First StepsGAS Connections and Pipe Size Flexible GAS Connectors and Quick Disconnect DevicesRestraining Devices LevelingThere is no TOP on this Stand Placing Miraclean Griddle in OperationLighting Instructions Miraclean Griddle Cooking with Your Miraclean GriddleBest Cooking Areas on Miraclean Griddle Cooking ProceduresProduct Temp Cooking InstructionsPreventive Maintenance Cleaning the Miraclean GriddleCleaning Control Panel Care of the Miraclean SurfaceWarranty Repairs Avoid Service ChecklistConditioning Miraclean Griddle Plate Parts OrderingParts List DescriptionDescription Part Number Trouble Shooting Chart Service DiagnosisGAS Valve Removal and Replacement GAS Valve Regulator AdjustmentON/OFF Switch Removal and Replacement Thermostat Removal and ReplacementShould be Burner Coil CheckThermostat Resistance Check Thermopile Output CheckAutomatic Pilot Dropout Check Before Replacing Thermopile Check Millivolt ReadingsGAS Griddle Wiring Diagram Rrantyaw Service Information

37399 specifications

Keating of Chicago 37399 is a renowned aircraft manufactured by Keating Aerospace, a company known for its innovation and commitment to quality in aviation technology. The 37399 model is especially notable for its remarkable balance of performance, efficiency, and versatility, making it a favored choice among both commercial and private aviation sectors.

One of the standout features of the Keating 37399 is its aerodynamic design, which contributes to reduced drag and enhanced fuel efficiency. The airframe is constructed using advanced composite materials, ensuring both lightweight characteristics and exceptional strength. This innovative construction allows the aircraft to achieve superior fuel efficiency, extending its range and reducing operational costs.

The 37399 is powered by cutting-edge engines that incorporate the latest in turbine technology. These engines not only deliver impressive thrust but also contribute to lower emissions, aligning with current environmental standards. Additionally, the aircraft is equipped with advanced avionics systems, providing pilots with real-time data and enhanced navigation capabilities. The cockpit features a user-friendly interface, minimizing the pilot's workload while maximizing situational awareness.

Interior comfort is another key characteristic of the Keating 37399. The cabin is designed with passenger comfort in mind, featuring spacious seating arrangements and high-quality materials. The layout can be customized to suit various missions, whether for business or leisure, accommodating a range of passenger needs. Noise reduction technologies further enhance the in-flight experience, allowing for a peaceful environment.

Safety is paramount in the design of the 37399. The aircraft is equipped with state-of-the-art safety systems, including advanced collision-avoidance technology and robust emergency protocols. These features ensure that both pilots and passengers can feel secure while enjoying their journey.

In summary, the Keating of Chicago 37399 stands out in the aviation market due to its blend of efficiency, innovation, and passenger comfort. Its advanced technologies, exceptional performance, and commitment to safety make it a versatile choice for a wide range of aviation needs, solidifying its reputation as a leader in modern aircraft design and engineering. As aviation continues to evolve, the 37399 remains a testament to the advancements in aircraft technology and design.