Miele DA 399-5, DA 398-5 installation instructions Plywood backing, To install a plywood backing

Page 26

Plywood backing

The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.

(If plywood backing is not needed, proceed to the included "Installation diagram".)

To install a plywood backing

￿Determine and mark the location of the retaining plate for the canopy as outlined on the "Installation diagram".

￿Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.

￿Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder.

￿Mark a vertical cutting line along the center of each stud.

￿CAUTION

When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

￿Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.

￿Proceed to the enclosed "Installation diagram" to complete the installation.

26

Image 26
Contents Operating and Installation Instructions Ventilation System Page Contents Important Safety Instructions Use To Reduce the Risk of a Cooktop Grease FireEvacuate and Call the Fire Department Installation Guide to the Ventilation System Overhead lighting Charcoal filter Air extraction Recirculation mode Functional descriptionAutomatically switching back the intensive power level Selecting the power levelIntensive setting OperationOverhead lighting Automatic Safety Shut-OffTurning off the fan Special instructions for colored casings Special order Cleaning and CareCleaning the casing Stainless steel colored controlsCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulb MieleCare After Sales ServiceRepairs Page Installation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material Appliance dimensions 125 mm Distance between cooktop and hood S Miele Cooktops Non-MieleDrilling diagram To install a plywood backing Plywood backingProtective film InstallationInstallation instructions DismantlingInstallation materials Protective shields Installation kit for recirculation modeInstallation instructions Vent collarElectrical connection Grounding InstructionsAir extraction Condensate trap Technical data Page Page Alteration rights reserved Nr 759 400