Miele DA5321D Installation, To reduce the risk of fire only use metal ductwork

Page 6

IMPORTANT SAFETY INSTRUCTIONS

Installation

~, WARNING

To reduce the risk of fire only use metal ductwork.

~Any fittings, sealant, or materials used to install the ductwork must be made of approved non-flammable materials.

~Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood:

22" (550 mm) above electric cooktops,

30" (762 mm) above gas cooktops,

26" (650 mm) above an open electric grill or an open electric boiler/fryer.

If local building codes require a greater safety distance, follow their requirement.

If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.

~Do not install this hood over cooktops burning solid fuel.

~Do not use an extension cord to connect the appliance to electricity. Extension cords do not guarantee the required safety of the appliance, (e.g. danger of overheating).

~Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room ventilating ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

~Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

~Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

~When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

~Ducted fans must always be vented to the outdoors.

6

Image 6 Contents
En US, CA Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkFunctional description Guide to the hood On/Off button Fan power level buttons Delayed Shut DownGrease filter button Automatically switching back the intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filter timer Checking the grease filter timerReprogramming the grease filter timer Stainless steel Cleaning and careCleaning the casing Stainless steel colored controlsRemoving the gr ease filter Cleaning the grease filter Changing the light bulbs MieleCare After Sales ServiceRepairs Http//store.miele.comInstallation Instructions Page Caring for the environment Disposal of packing materialDisposal of an old appliance Appliance dimensions Appliance dimensions Structural support Installation accessories Installation instructionsInstallation accessories Air extraction Condensate trap Electrical data This Appliance Must be Grounded