Scotsman Ice FME 1204 warranty Condenser, Air, Psig, Electrical Voltage +10%

Page 2

BACK VIEW

AIR

CONDENSER3/8(WATERREMOTE3/8(REMOTEINALE-IN1.COOLED0-COUPLING1CMLIQUID.0ONLY)CMINLETF.P..ONLY)INLET

BACKWATERVIEW& 208452.9CMIN REMOTE

 

 

 

Ice Machine Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.00IN/15.2CMMIN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UTILITYCONNECTIONS

 

 

 

 

 

 

 

 

 

 

ICECHUTE

 

 

 

 

 

 

 

EXHAUSTAIR

 

 

 

 

ELECTRICALINLET

 

OPENING

275IN

 

 

 

6.20IN

 

 

 

 

 

 

9.50IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.0CM

 

 

 

15.7CM

 

 

EXHAUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37.00.6CMIN

5.25IN

24.1CM

 

 

 

 

 

275IN

 

 

INLET

3/4"FPT

 

13.3CM

 

 

 

 

5.75IN

 

PLANVIEW

7.0CM

 

 

 

5.3CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.6CM

 

 

 

BACKVIEWWATER&REMOTE

DRAIN

 

2.10IN

 

 

 

 

 

 

 

 

 

 

 

3/8"FLARE

 

 

5.87IN

 

 

 

 

 

 

 

 

 

 

 

 

BACKVIEWAIR

5.7CM

 

 

 

 

 

 

 

 

 

 

 

 

 

310IN

 

14.9CM

2.26IN

 

 

 

 

 

 

 

PLAN VIEW

 

 

 

 

7.9CM

 

 

380IN

REMALCOUPLINDISCHAREGOUTLET

 

 

 

 

 

240IN

2100IN

 

 

 

 

 

 

9.7CM

 

 

 

 

 

61.0CM

53.3CM

 

 

 

 

 

 

 

(REMOTEONLY)CONDENSER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2in-1.3cm

ONLY)BOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICALINLJUNCTION(REMOTE

4.50IN

 

 

 

 

 

 

2700IN

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

WATERINLET

 

11.4CM

 

INTAKE

 

 

 

 

68.6CM

 

 

 

 

 

 

 

3/8IN-1.0CMFLARE

7.30IN

1243IN

 

 

 

 

 

 

 

 

 

 

 

 

 

5.25IN

31.6CM

 

 

 

 

 

 

 

 

 

 

 

 

300IN

18.5CM

 

 

 

 

 

 

 

 

 

 

 

 

 

13.3CM

 

 

 

 

 

 

 

 

 

 

1/2IN-1.3CMF.P.T.

 

 

 

 

7.6CM

 

 

 

 

 

 

 

 

 

 

NE654/954

CONDENSERDRAIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WATERCOOLEDONLY)F3/4DRAIN.P.T.-1.9BACKCMVIEWWATER&REMOTE261027.1CMIN

114.66266.8CM.8INCMIN

 

 

 

LOUVEREDACCESSPANEL

 

SIDE VIEWSIDEVIEW

FRONTFRONTVIEWVIEW

FME804/1204

 

All models: Dimensions: W x D x H

Unit: 21˝ x 24˝ x 27˝ Shipping Carton: 241/4˝ x 271/2˝ x 32˝

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Water Usage

 

 

 

 

Basic

Max. Fuse

 

 

Min.

Shipping

Consumption

Gallons/100 lbs.

 

 

Model

Condenser

Electrical

Size or HACR

Comp.

Circuit

Circuit

Weight

KWH/100 lbs.

Potable

Condenser

 

 

Number

Unit

Volts/Hz/Phase

Circuit Breaker

HP

Wires

Ampacity

lbs./kg.

90°F/70° F

90°F/70° F

90°F/70° F

 

 

FME1204AS-32B

Air

208-230/60/1

15

1 1/2

2

11.3

215/98

3.26

12

 

 

FME1204WS-32B

Water

208-230/60/1

15

1 1/2

2

10.8

210/95

2.45

12

66

 

 

FME1204RS-32B

Remote

208-230/60/1

20

1 1/2

2

14.1

230/104

3.40

12

 

 

FME1204AS-3B

Air

208-230/60/3

15

1 1/2

3

8.4

210/95

3.0

12

 

 

FME1204WS-3B

Water

208-230/60/3

15

1 1/2

3

7.9

230/104

2.19

12

66

 

 

FME1204RS-3B

Remote

208-230/60/3

15

1 1/2

3

11.2

230/104

3.2

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All units with Stainless Steel finish.

Refrigerant: R-404A.

REMOTE CONDENSER–Comes with adjustable legs Dimensions: W x D x H: 24.00˝ x 44.25˝ x 29.25˝ for ERC151

24.00˝ x 44.25˝ x 29.25˝ for ERC302

 

 

 

 

 

 

 

Max Fuse

 

 

 

 

Electrical

 

Min. Circuit

Size or

Model

 

 

Finish

Volts/Hz/

 

Ampacity

HACR Circuit

Number

For Use With

Cond. Unit

Basic

Phase

No. of Wires

 

Braker

ERC151-32A

(1) FME1204

Air

Galvanized

208-230/60/1

2

2.6

15

ERC302-32A*

(2) FME1204

Air

Galvanized

208-230/60/1

2

2.6

15

PRE-CHARGED REFRIGERANT TUBE KITS: 25-Foot, RTE25 • 40-Foot, RTE40 • 75-Foot, RTE75, Refrigerant: R-404A.

*KCMR-230—Fan Relay Kit: Required to connect two FME1204’s to one 302-32A

Scotsman’s ice machines are not designed for outdoor installations. Scotsman remote condensers are designed for outdoor installations.

Machine requires voltage indicated on rating name plate. Failures caused by improper voltage are not considered factory defects. Extended periods of operation at temperatures exceeding limitations constitutes misuse under the terms of Scotsman Manufacturer’s Limited Warranty, resulting in a loss of warranty coverage. Specifications and design are subject to change without notice.

IMPORTANT OPERATING REQUIREMENTS:

 

Minimum

Maximum

Air Temperatures

500F (100C)

1000F (37.70C)

Water Temperatures

400F (4.40C)

1000F (37.70C)

Remote Cond. Temps

-200F (-28.90C)

1200F (48.90C)

Water Pressures

20 PSIG

120 PSIG

Electrical Voltage

-5%

+10%

Consult Your Local SCOTSMAN Representative At:

Y O U ’ L L V A L U E T H E D I F F E R E N C E TM.

775 Corporate Woods Parkway • Vernon Hills, IL 60061 • 1-800-SCOTSMAN • Fax: (847) 913-9844

Visit our website at: www.scotsman-ice.comE-mail: customer.service@scotsman-ice.com

SF-1204-1 4M 6-06

Image 2
Contents Used in produce and fish TemperaturesInexpensive to produce ModelPsig CondenserAir Electrical Voltage +10%