Vulcan-Hart GHF91G ML-135503, GHF90G ML-135504 service manual FRY Tank

Page 8

FRY TANK

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Disconnect fryer from main gas supply.

2.Drain oil from tank.

3.Remove baskets, fryer basket hanger and crumb screen.

4.Remove screws holding fry tank.

5.Remove burners as outlined under Burners.

6.Remove the manifold bracket from the tank assembly.

7.Remove thermostat and high limit as outlined under Thermostat and High Limit.

8.Remove screws holding pilot assembly to bracket and remove pilot assembly.

9.Lift the fry tank up and out of cabinet. Carefully place the tank assembly on the floor (this procedure requires two people).

10.Remove the tank ball drain valve.

11.Reverse the procedure to install new tank.

– 8 –

Image 8
Contents GHF Series Heavy Duty Range Matching GAS Fryers & Frymates Table of Contents Specifications GeneralIntroduction ToolsRemoval and Replacement of Parts Covers and PanelsBurners DoorThermostat High Limit ThermopilePilot Orifice Combination ValveFRY Tank Service Procedures and Adjustments Millivolt Controls TestThermostat Calibration Calibration StepsPilot Adjustment BURNERS, Nozzles and OrificesBurners Nozzles and OrificesCombination Valve Regulator Adjustment Control System Description System Condition Quick Check ProceduresElectrical Operation Schematic Component Function Troubleshooting Symptom Possible CauseTroubleshooting Form 35618