MAINTENANCE

WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE STEAMER.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.

DELIMING

Refer to the water filter manual shipped in the box with your steamer.

LUBRICATION

Once each month, lubricate the thrust screw of each compartment door. To access the thrust screw, open compartment door and turn handwheel fully clockwise until gasket plate is fully extended. Grasp finger hooks and lift up to remove gasket plate assembly. Apply grease (order part 880786 from your Vulcan servicer) to the thrust screw while rotating the handwheel to assure complete coverage. Replace gasket plate assembly. Turn handwheel fully counterclockwise to retract gasket plate into door. Close door.

DOOR GASKET

If the door gasket becomes damaged from nicks or cuts and steam leakage results, contact your Vulcan-authorized servicer to have the gasket replaced.

SERVICE

Contact your local Vulcan-authorized service office for any repairs or adjustments needed on this equipment.

FORM 30914 Rev. A (Jan. 2003)

– 12 –

PRINTED IN U.S.A.

Image 12
Contents Installation VSC Series Steamers With Steam Coil Regenerator VULCAN-HART Company General AccommodationInstallation Plumbing Connections Steam Connection Required Steam InputSteam LINE-PRESSURE Loss Equivalents Service Connections Electrical ConnectionsOperation Compartment Controls FigSteam Regenerator Controls Inside Cabinet SteamingPreheat Compartments Cooking Guidelines Other FoodsCleaning Maintenance ServiceDeliming Lubrication