Trane 22-5214-03 manual Problem Solver, Extra Energy Tips, Insulation, Heating, Cooling

Page 6

The Problem Solver

Before you call for service, check the following:

Problem

Possible cause

Remedy

Insufficient heating

a. dirty filters

a. clean or replace

or cooling

b. air not circulating freely

b. check supply registers and return

 

 

grills for blockage

 

c. blocked outdoor coil

c. clear away leaves or other debris

 

 

 

Failure to operate

a. power off

a. make sure main switch is in

 

 

ON position

 

b. open circuit breaker or

b. reset circuit breaker, or replace

 

burned-out fuses

burned-out fuses

 

c. improperly adjusted

c. check setting, adjust thermostat

 

thermostat

 

 

 

 

Blue auxiliary heat

When outdoor temperature

Monitor light. If it stays on continuously

light on

falls, intermittent lighting

when above 30°F, or if it comes on

 

is normal

when 50°F outdoors, call for service.

 

 

 

No Heating or

Blower door removed

Close door securely to restore power

Cooling – Blower

or ajar

to blower

does not operate

 

 

 

 

 

Unusual Noise

 

Call your local servicer

 

 

 

Reduce the burden of unexpected repair bills with a Trane Extended Warranty.

Trane offers the finest quality products and manufacturer’s warranties on the market. But, like all good things, the Trane-provided limited warranty on your new comfort equipment will come to an end. To keep you protected, Trane offers the Extended Warranty Program. It picks up right where your Trane lim- ited warranty leaves off. And, it offers years and years of reliable protection at a low cost. Ask your dealer for program details.

Extra Energy Tips

Insulation

1.Make sure your home is properly insulated. This is the single most important step in conserving en- ergy. Thermal insulation should be specified in terms of thermal resistance (R-values). R-30 (10") is recommended for ceilings, R-11 (3-1/2") for exterior walls and floors over unheated areas. In colder climates, consider additional insulation.

2.Infiltration of humid outside air is your heating and cooling system’s worst enemy — it could account for 15 to 30% of air conditioning energy requirements. Find the places where air can sneak into the home and plug them with caulking, weather-stripping or plastic. Also, weather-strip and caulk around all entrance doors and windows.

3.Cut heat transfer through your windows by 40 to 50% with double glazing (two panes of glass sepa- rated by a sealed air space) and low-e glass.

4.Use wood- or metal-frame storm windows even if single-glazed win- dows are high quality. The

extra layer of glass and the layer

of still air will cut heat transfer con- siderably.

5.Install storm doors at all entrances to your house.

6.Keep all windows and doors closed.

7.Remember that by increasing the glass area, you increase the amount of heat added in summer and lost

in winter.

8.Make sure fireplaces have tight- fitting dampers which can be closed when the fireplace is not in use.

9.Invest in a humidifier to conserve energy in winter. The air in your home won’t be as dry, so you stay comfortable at a lower temperature setting.

Heating

10.Locate the thermostat on an inside wall away from windows and doors.

11.Set the thermostat as low as wcom- fort permits. Each degree over 68°F can add 3% to the amount of energy needed for heating.

12.People generate heat. So lower the thermostat a degree or two when expecting a large group of guests.

Cooling

13.Set the thermostat as high as com- fort will permit.

14.Make sure attics are adequately ventilated to relieve heat buildup. If necessary, improve airflow by adding or enlarging vents.

15.When building a new house or renovating an old one, choose light-colored roof shingles to reflect more of the sun’s heat.

16.During moderate weather, don’t use the system unnecessarily.

17.Draw blinds or drapes to block the sunlight during the hottest part of the day.

18.Install awnings over windows ex- posed to direct sunlight.

19.In the cooling season, don’t run kitchen and bath exhaust fans longer than necessary.

20.Don’t place lamps, TV sets or other heat producing devices beneath a wall-mounted thermostat. Rising heat from the equipment may cause the system to over-cool your house.

6

22-5214-03

Image 6
Contents Use and Care Outdoor UnitContents Warranties ResidentialWarranties Commercial Models Less than 20 Tons for Commercial USE Parts onlyAttn Customer Relations TW-1024-3308 Proper maintenance for maximum efficiency How it works to keep you comfortableProper maintenance How to operate your system for peak performanceInsulation Problem SolverExtra Energy Tips HeatingExtended Warranty Application Important Service Information Service Information12-08

22-5214-03 specifications

The Trane 22-5214-03 is a high-performance compressor designed specifically for residential and commercial air conditioning systems. This component plays a critical role in the overall efficiency and reliability of HVAC systems. The Trane brand is renowned for its commitment to quality, innovation, and energy efficiency, making the 22-5214-03 a popular choice among contractors and engineers.

One of the main features of the Trane 22-5214-03 is its advanced scroll compressor technology. Scroll compressors are designed to provide a quieter operation and better energy efficiency compared to traditional reciprocating compressors. This technology has fewer moving parts, which not only enhances durability but also minimizes maintenance requirements and operational noise levels.

In terms of energy efficiency, the Trane 22-5214-03 is engineered to meet or exceed the latest energy efficiency standards, such as SEER (Seasonal Energy Efficiency Ratio) ratings. By utilizing a high-efficiency design, the compressor helps reduce energy consumption, leading to lower utility bills for homeowners and businesses. This focus on energy efficiency also has a positive impact on the environment, as reduced energy consumption translates into lower greenhouse gas emissions.

The durability of the Trane 22-5214-03 is another key characteristic. Constructed with high-quality materials and innovative engineering, this compressor is built to withstand harsh operating conditions, making it a reliable choice for both residential and commercial applications. The manufacturer incorporates features like a robust shell design and enhanced insulation to protect the internal components from wear and tear, extending the lifespan of the unit.

Moreover, the Trane 22-5214-03 boasts enhanced refrigerant compatibility, which allows it to work efficiently with modern refrigerants. This adaptability is crucial as regulations evolve and focus increasingly shifts towards eco-friendly refrigerant options.

In summary, the Trane 22-5214-03 is a state-of-the-art compressor that integrates advanced scroll technology, energy efficiency, and robust durability. It is an optimal choice for those seeking reliable HVAC solutions that minimize energy costs while maintaining high performance and longevity. Whether for new installations or replacements, this compressor exemplifies Trane’s dedication to delivering exceptional heating and cooling solutions.