For rear entry connection on 3-10 Litre models, we recommend that you use a braided flexible hose with a 90° elbow for ease of connection.

F.OVERFLOW / VENT CONNECTION IMPORTANCE

Connect a 15 mm (½”) pipe to the overflow/vent connection (½”BSP nipple). This pipe is to be made of a material such that continuous steam will not degrade it (i.e. copper). This pipe must have a continuous fall, not exceeding 3 metres in length and / or contain no more than 4 bends (refer to figure 2).

Figure 1: Water Connection

If the site situation requires a pipe length exceeding 3 metres, then discharge the overflow/drain into a tundish.

The drain pipe work must not exert a pressure of more than 1 metre of head on the Lazer boiling unit (refer to figure 2).

During normal operation of the Lazer, the overflow/vent connection may discharge small quantities of steam and condensate, so it is ESSENTIAL that the drain pipe is attached to the overflow vent connection. This drain pipe must discharge to waste at a point where no scald injury, nuisance nor inconvenience is caused to people in the immediate vicinity.

Manual backgroundWARNINGS:

Ensure the overflow/vent line remains open because the Lazer’s tank is not designed to be pressurised. Where freezing may occur, protect the pipes and install an air break. It is recommended to install an air break in the overflow/vent drain line, no more than 300 mm from the Lazer unit. Also it is important to connect the overflow/vent and water inlet correctly. Incorrect connection of pipe work may damage the unit.

G. DRAIN

Manual backgroundWARNING:

Before draining the unit, ensure the appliance has been switched off, and water is not hot enough to scald.

To drain 3-10L models, turn unit off and open tap until no water flows out. Remove unit from wall and tip over with tap open until unit is empty. For 15-40L units. A drain plug is accessible from the bottom of the unit (note switch unit off before draining)

IMPORTANT

Installation and maintenance of the Lazer Boiling Water unit shall be carried out by a qualified service person.

Your closest Rheem Service Centre can be contacted by

telephoning 131 031

4.

Image 4
Contents OWNERS GUIDE & INSTALLATION INSTRUCTIONS CLASSIC SERIESModels 3, 5, 7.5, 10, 15, 25, & 40 Litre Models 7.5, 10, 15, 25, & 40 LitreCONTENTS DIMENSION SPECIFICATION FOR ALL MODELS - drawingINSTALLATION AND OWNERS GUIDE 3. INSTALLATIONLAZER BOILING WATER UNIT 2. WATER QUALITYtelephoning SPECIFICATION 4. OPERATIONH. TAP OUTLET J. ELECTRICAL REQUIREMENTSMOUNTING DIMENSION SPECIFICATION All modelsFigure 3 Mounting Dimension Specifications Classic ModelsClassic models DIMENSION SPECIFICATIONFigure 4 Dimension Specification Timer Functions A Setting the ClockB Set Timer to STD/AUTO Mode To select a Timer ModeF To Service Menu i.Remaining Life ii.Filter Reset iii.Filter Lifei.Error Codes ii.Boiling Temp iii.Chiller Temp iv.Calib Reset v.Software VersionLAZER BOILING WATER UNIT FAULT FINDING GUIDE SYMPTOMSPOSSIBLE CAUSE REMEDYPage WARRANTY WARRANTY PERIODWARRANTY CONDITIONS WARRANTY EXCLUSIONS