Pentair SM/SMBW 2000 How to Clean Filter Manually & Winterizing Instructions

Page 14

8

How to Clean Filter Manually & Winterizing Instructions

(Required at least once a year and when winterizing your filter to prevent damage during freezing conditions.)

1.Turn pump off.

2.Set valve handle or valves for backwash position, (for SMBW only).

3.STAND CLEAR OF THE FILTER - Turn pump on and run for 3 minutes, then turn pump off.

4.Drain filter with respect to opening the air relief valves as discussed in a, b, and c, below.

a.To drain filter Model SM with gate valves, open drain valve and tank air relief valve and close all other valves.

WARNING — Valve "D" is the air relief valve. It is important that this valve be opened before proceeding

further. The tank is pressurized and is dangerous if the air is not vented prior to removing the lid clamp. Failure to open the air relief valve could cause the lid to separate resulting is serious bodily injury and/or property damage.

b.To drain filter model SMBW, set valve handle to backwash position and open tank air relief valve.

c.To drain filter model SMBW with Separation Tank, set valve handle to backwash position; open tank air relief valve; close all other valves and remove drain plug on backwash line.

5.To remove the clamping ring, partially unscrew the adjustment knob and release the head of the T-bolt from the slotted bracket.

6.Remove tank lid with screwdriver or with a tool available from the manufacturer, see page 9, Figure 5. Avoid cutting rubber O-ring or bending of lid or tank O-ring channel.

7.Use garden hose to rinse down filter elements until all debris has been flushed from tank. Then screw drain plug on backwash line on models with Separation Tank.

8.Unscrew wing nut; remove washer and unclip air vent tube from holding wheel. Remove holding wheel.

WARNING — Please heed all manufacturers' posted instructions, warnings and cautions when using muriatic acid.

9.Lift out filter elements and scrub each element with a soft brush. If elements are coated with scale, it will be necessary to brush with a mild solution of muriatic acid (10 parts water to 1 part muriatic acid). Rinse elements with water.

10.Remove manifold and inspect for damage. Replace rotor O-ring & lubricate as needed.

11.Replace clean elements in manifold sockets; notch on element will guide it to proper position. All elements are interchangeable.

12.Replace holding wheel over center rod; place washer over rod and turn holding wheel until elements spread to widest gap. Replace washer, then screw wing nut on rod. Do not tighten nut beyond finger tight. Be sure to clip air vent tube back into slot on holding wheel. Clean vent tube screen cap of any debris.

13.Remove rubber O-ring and clean both O-ring and channel. Lubricate O-ring with a non-water soluble grease or silicone lubricant and replace O-ring in channel.

14.Clean the inside surface of the tank lid where it seals against the O-ring. Place lid on tank; push down on lid to seat in place.

15.Replace the clamping ring. Engage the head of the T-bolt into the slotted bracket and tighten the adjustment knob. (Hand tighten only.)

16.To restore to the filter cycle, refer to the operating and cleaning instructions of the filter model involved. When winterizing, ensure that all water is removed from the lower internal portion of the filter.

SM/SMBW 2000 Series™ Filter Installation and User’s Guide

Image 14
Contents Installation Users Guide Web site Phone 800 Fax 800Table of Contents Consumer Information and Safety Important NoticeIii Post a warning signGeneral Installation Information Section Introduction SM/SMBW 2000 Series Filter OverviewGeneral Features Additional FeaturesSection Filter Operation General InformationDiatomaceous Earth D.E What is Diatomaceous Earth and how does it Filter WaterFilter Precoating Instruction Precoat RequirementsSection Filter Installation General Filter InformationHow to Operate Filter Section Maintenance To Backwash Clean FilterHow to Clean Filter Manually & Winterizing Instructions How to Use the Filter Lid Opener Tool Section Troubleshooting Symptoms What to Look for Recommended ActionFlow Rate Table Section Replacement PartsReplacement Parts List Model SM/SMBW 2000 Series FilterHead Loss Comparison Curves Rotary Valve Model Smbw w/ Noryl RotorSM/SMBW2000 075122 Rev. E 4/5/06

SM/SMBW 2000 specifications

The Pentair SM/SMBW 2000 series represents a significant advancement in water treatment and filtration technology, specifically designed for both commercial and industrial applications. This system is engineered to deliver high-quality water while ensuring operational efficiency and reliability.

One of the standout features of the Pentair SM/SMBW 2000 is its versatile design, which accommodates a wide range of applications including process water, cooling water, and waste reduction, making it ideal for various industries. The system integrates advanced filtration technology, ensuring the removal of contaminants, particulates, and other unwanted substances to produce clean, high-purity water.

The system is equipped with state-of-the-art sensor technology that allows for real-time monitoring and management of operational parameters. This feature not only enhances the system’s performance but also enables users to respond swiftly to any deviations, ensuring consistent water quality. The modular design of the SM/SMBW 2000 also contributes to its user-friendly nature, allowing for easy maintenance, upgrades, and adaptability to changing water quality needs.

In terms of energy efficiency, the Pentair SM/SMBW 2000 is designed to minimize energy consumption without compromising on performance. Its advanced control systems optimize pump operation and filtration processes, which results in lower operational costs and reduced environmental impact.

Moreover, the SM/SMBW series is built with robust materials that are resistant to corrosion and wear, ensuring longevity in demanding environments. This characteristic is essential for industries where equipment reliability is critical.

The SM/SMBW 2000 systems also feature an intelligent automation system. This smart technology not only enhances operational efficiency but also provides valuable insights into system performance and water quality through comprehensive data reporting. Users can adjust settings remotely, leading to increased convenience and operational efficiency.

In summary, the Pentair SM/SMBW 2000 series combines advanced filtration technology, energy efficiency, and intelligent monitoring to provide superior water treatment solutions for various commercial and industrial applications. Its reliability, ease of use, and adaptability make it a noteworthy choice for those seeking to optimize water quality and operational performance in their facilities. As water quality standards continue to evolve, the Pentair SM/SMBW 2000 stands ready to meet and exceed the challenges faced by today's water treatment demands.