(3/3)
TENSILE STRENGTH OF TERMINAL
CENTER MOUNTING
It shall be not broken after a tensile force of 1 mm is applied to the terminal in the direction of axis for 5±1seconds.
20
R340
45
| gap±0.1 | 1 |
|
| 45 |
|
| |
|
|
|
PCB(FR4)thickness : 0.8 mm Dimensions in mm
SIDE MOUNTING
It shall be not broken after a tensile force of 2 mm is applied to the terminal in the direction of axis for 5±1seconds.
45
20
R340
40
|
| gap±0.1 | 2 | |
|
|
| 45 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
PCB(FR4)thickness : 0.8 mm Dimensions in mm
The tested antenna is offset by 40 mm from the position where the tensile force is applied.
• All specifications are subject to change without notice.