Toshiba ST-7000-C Series owner manual Installation Procedure, Environment for Installation

Page 11

4. INSTALLATION PROCEDURE

EO1-12030

4.1 Environment for Installation

4. INSTALLATION PROCEDURE

4.1 Environment for Installation

1.Provide a space of minimum 80 mm to the left, right, front, rear, and top of the main unit for proper cooling. (The main unit has air vents on the front, rear, right and left, and a fan. Spaces should be provided to prevent the air vents in the main unit from being closed and the air flow from being obstructed.)

2.Attaching the cable cover:

The cable cover must be attached to protect the interface cables or connectors. Be sure to turn off the power before connecting or disconnecting the cables.

3.Notes on installing the display unit on the top of the enclosure:

When installing the display unit on the top of the enclosure, the following conditions must be satisfied. (Except for the standard display unit)

1)Display unit weighing 12Kg or under

2)The base of the display unit has no projections that might damage the enclosure.

3)The base of the display unit does not protrude beyond the steel plate at the top of the main unit.

4.2 Attaching the Cable Cover

1.Insert the guides on both sides of the cable cover into the slits provided on the POS terminal, then slide down the cable cover to the bottom.

NOTE: Be sure to attach the cable cover for protecting the cables.

GuideSlit

Cable Cover

2.When detaching the cable cover, hold both sides by hands, then pull it up.

4- 1

Image 11
Contents ST-7000C Series Page CE Compliance for EU only Waste Recycling information for users Safety Summary Precautions Table of Contents Introduction Accessories#Front View AppearanceConnector Description ConnectorsAttaching the Cable Cover Installation ProcedureEnvironment for Installation HOW to LOCK/UNLOCK the Front Panel Cleaning the Covers General MaintenanceCleaning# Symptom Check point Solution TroubleshootingDescription SpecificationsBasic Specifications Option name Type Options