ZGU36N6HSS (Natural Gas)
ZGU36L6HSS (Liquid Propane) – GE Monogram 36" Professional Gas Cooktop with 6 Burners
Backsplash Accessories
The cooktop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom,
ZX12B36HSS, 12" backsplash
ZX22B36HSS, 22" backsplash with warming shelf
Backsplash with Warming Shelf
All Monogram® Professional Hoods feature infrared warming lights. The
•
Side View with a Backsplash
| 12" Min. to Combustibles or | |||
|
| 0" Min. to Combustibles | ||
3/4" |
|
| ||
|
| with 12" or 22" Backsplash | ||
| 22" High | 36" Min. | ||
| 36" Min. | |||
22" | to Combustibles | |||
Backsplash | ||||
| with Shelf |
| to | |
12" |
| Combustibles | ||
12" High Backsplash | ||||
| ||||
|
|
0" Clearance
Advance Planning for 36"
Professional Cooktops
Professional cooktops offer a number of choices in size and cooktop configurations.
•All Professional cooktops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
Note: Conversion kits (WB49X10132, Nat. to LP and WB49X10133, LP to Nat.) are available if the wrong gas type was ordered. High Altitude kit, WB49X10130, is also available. The kits must be installed by a qualified service technician at additional cost.
Locate gas |
| 2" |
|
|
|
|
|
|
|
|
| ||
7" |
|
|
|
| ||
|
|
|
| |||
inlet on |
|
|
|
|
| 16" |
|
|
|
|
| ||
back wall |
|
| ||||
|
|
|
| |||
|
|
|
|
|
| |
or on floor |
|
|
|
|
|
|
2" from |
|
|
|
|
|
|
back wall |
|
|
|
|
|
|
Electrical Requirements
Cooktops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or
Gas Supply
•Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the cooktop regulator.
•The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the cooktop regulator.