Model USGF is a leader in severe wind and severe grease applications. The USGF has been subjected to Miami-Dade test protocols TAS-201/202/203 for wind pressure and missile impact. After extensive testing exceeding all standards the USGF was still in operating condition. The USGF is UL/cUL listed for restaurant exhaust with continuous operation at 400ºF. The unit is constructed entirely of steel and includes a non-stick coated steel wheel, NEMA-3R disconnect, hinged base assembly, and clean out port. Making the USGF ideal in high wind applications. Performance is AMCA certifi ed to 7,000 cfm and up to 3 inches wg.

Models LDP/LBP are the only rooftop exhaust fan that can withstand design pressures in excess of 140 PSF. The LDP/LBP with SDLE enclosure passes all Miami-Dade and Florida Building Code requirements (TAS-201/202/203). The severe duty LDP/LBP is constructed of Miami- Dade approved louvers (model ESD-603D) with a high strength structural steel support frame, and ships mounted to a 12 gauge steel curb. For applications requiring missile impact resistance turn to the Greenheck severe duty LDP/LBP for all your exhausting needs. Performance on these units is AMCA certifi ed and ranges from 100 up to 14,200 cfm and up to 1.25 inches wg.

Model RSFP is the only rooftop centrifugal supply fan that can withstand design pressures in excess of 140 PSF. The RSFP with SDLE enclosure passes all Miami-Dade and Florida Building Code requirements (TAS-201/202/203). The severe duty RSFP is constructed of Miami-Dade approved louvers (model ESD-603D) with a high strength structural steel support frame, and ships mounted to a 12 gauge steel curb. For untempered supply applications with missile impact resistance turn to the Greenheck severe duty RSFP. Performance on these units is AMCA certifi ed and ranges from 650 up to 14,300 cfm and up to 2 inches wg.

The Severe Duty Louver line is the most diverse in the industry. We were

rst to offer a Miami-Dade qualifi ed Severe Duty Louvered Enclosure (model SDLE) and offer three Miami-Dade qualifi ed louver models as well. With the ability to complete Large Missile Impact and Wind-Driven Rain Testing in- house, we continue to accelerate our product development and remain an

industry leader.

The Vektor product line is used in applications requiring dilution of exhaust air or high plume rise above the roof line. Common applications include laboratory exhaust, odor control and kitchen exhaust. Vektor models are AMCA certifi ed and UL/cUL listed. Fan systems are rated to withstand 125 MPH wind loading without the use of guy wires. Vektor product line meets NFPA, ANSI Z9.7, and ASHRAE code requirements and guidelines for laboratory exhaust systems.

Whether your application calls for meeting a high wind load, impact resistance, or resistance to the penetration of wind-driven rain, Greenheck has the solution.

P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com

Promo High Wind & Hurricane Fans RG

Rev. 2 November 2006

Copyright © 2006 Greenheck

Image 8
Contents High Wind and Hurricane Zone Fans Withstands winds up to 150 MPH Standard ConstructionThird Party Testing and Certifications Concrete Deck Anchoring Typical InstallationFan to Curb Mounting Metal Building/Steel Deck Anchoring Wood Deck AnchoringSpecifications Centrifugal Downblast Roof Exhaust FansDirect Drive GB Belt DriveCube Belt Drive Centrifugal Upblast Roof Exhaust FansCUE Direct Drive Severe Duty Products