Fisher & Paykel E402B, E442B installation instructions Installation instructions, PRV connection

Page 7

Installation instructions

5

Installation instructions:

1Ensure that refrigerator is not plugged into a power supply.

2 Remove the compressor compartment cover from the rear of the refrigerator (USA market only).

3 Locate isolation tap for water connection – cold water feed only (dishwasher or sink mixer taps) – if you can’t find the connection tap, contact an authorised plumber in your state or town to fit your water connection.

4 Connect the 200 mm (8”) blue tubing to the outlet of the PRV (blue collet) and the inlet connection of the water filter cartridge as shown in Diagram 1. Gently pull on both ends to ensure it is locked.

5 Connect the white 6 mm (¼”) tubing to the outlet of the water filter cartridge as shown in Diagram 2. Gently pull to ensure it is locked.

6 Measure the required length of tubing to run from the PRV to the water connection point.

7 Cut the tubing making sure the ends are square and clean. 8 Connect the tubing to the tap connection and the base

of the PRV (white collet) and then to the tap as shown in Diagram 3. Please note that the tap connection supplied should fit most installation situations. If your tap requires a different fitting, please contact an authorised plumber in your state or town to purchase the correct fitting.

9 Connect one locking key to each side of the water filter cartridge in between the cartridge and the locking collet as shown in Diagram 4.

10 To flush the water filter and check for leaks, aim the end of the tubing into a bucket, turn isolating tap on and run at least 3 litres (3 qt) of water through. Once complete, turn isolating tap off.

11 Locate desired position for water filter noting carefully the following points:

It is recommended to fit the filter in a vertical orientation with the water filter head at the top. This will minimise water leakage when replacing cartridge. Ensure the filter is in a convenient location to access every 6 months for replacement. We suggest that

this location is beside the water filter supply tap in the cupboard beside the refrigerator.

A minimum clearance of 64 mm (2 ½”) from the bottom of the filter cartridge is required to perform cartridge removal.

Do not screw filter to fridge.

Diagram 1

Fig.4 PRV connection

Diagram 2

Fig.5 Waterline connection

Diagram 3

Fig.6 Tap connection

Diagram 4

Fig.7 Locking key

Image 7
Contents Installation instructions and user guide Introduction Before you start using your Ice & Water refrigeratorContents Disposal Important safety instructions Electrical Cleaning Power failure food safetyStoring food and drinks Contents of kit Installation instructionsPRV connection Installation instructionsDouble sided foam attachment Connection to water supply Main menu All about the displayKeys Measured Fill seeTemperature see Display features Measured Fill seeSettings/User alerts see Dispensing Using your water dispenserDispensing pad First useIce maker Using your ice makerNoises Ice storage bin and scoop in correct position Information about your ice makerMeasured Fill Fridge optionsChanging the Measured Fill units Bottle Chill Freezer ChillRecommended times Bottle Chill contd Temperature of your refrigerator and freezerWater unit conversion SettingsUser warnings Once in Sabbath ModeFilter reset FaultChanging the water filter cartridge Water filterTo disable filter indicator To reset filter indicatorMeasured Fill Calibration Measured Fill CalibrationCalibration quick reference guides Trouble shooting Does not work Water has poorTaste/odour Water dispenserWater dispenser pad and interface On vacation/holidayAutomatic ice dispenser Australia If You Need Assistance Manufacturers warrantyBefore you call for service or assistance New Zealand If You Need AssistanceUSA If You Need Assistance Ireland If You Need AssistanceFor the Rest of the World… Europe If You Need Assistance1806 Usepa MCL Page Page Copyright Fisher & Paykel 2006. All rights reserved