Fisher & Paykel GC9002 dimensions DimensionsClearances, Product Dimensions, Cutout Dimensions

Page 2

DimensionsClearances

PRODUCT DIMENSIONS

 

GC600

GC9002

CG901M

Width

578mm

914mm

914mm

Depth

511mm

533mm

546mm

Height

40mm

40mm

76mm

Note Height measurement below bench surface.

CUTOUT DIMENSIONS

 

 

GC600

GC9002

CG901M

A

Width

560-564mm

846-882mm

860-895mm

B

Depth

485-495mm

478-501mm

486-524mm

C

Side Clearances*

140mm

140mm

118mm

D

Rear Clearance*

100mm

100mm

120mm

E

Entry from Side

50mm

50mm

25mm

F

Entry from Back

30mm

30mm

25mm

G

Clearance Below* 60mm

60mm

81mm

 

Bench

 

 

 

*Minimum clearance for cutout to combustible surface.

When used with a flexible hose, the connector on the wall should be between 800mm to 850mm above the floor and in the region outside the width of the appliance to a distance of 250mm. This should be accessable with the appliance installed.

RANGEHOOD CLEARANCE (Dimension A)

[See A.G.A. 601 5.12.1.6]

Dimension A (Measured from the plane of the pan supports to Rangehood) should not be less than 650mm.

Any other downward facing combustible surface less than 600mm above the highest part of the hob

shall be protected for the full width and depth of the cooking surface area.

However, in no case should this clearance to any surface be less than 450mm.

SIDE CLEARANCE (Dimensions B & C)

Where Dimension B, measured from the periphery of the nearest burner to any vertical combustible surface, is less than 200mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a Height C of not less than 150mm above the hob for the full dimension (width or depth) of the cooking surface area.

Do use easy-to-clean finishes for the wall surfaces surrounding the cooktop to aid removal of any cooking stains resulting from use of the cooktop.

A.G.A. Clause 5.12.1.2.

A.G.A. Clause 5.12.1.2. Protection of a Combustible Surface Near a Cooking Appliance.

The protection required by clause 5.12.1.1. shall ensure the surface temperature of the combustible surface does not exceed 50°C above ambient.

Note The fixing of 5mm thick ceramic tiles to the surface or attaching fire resistant materials to the surface and covering with sheet metal with a minimum thickness of 1.4mm would satisfy this requirement.

CLAMPING DOWN THE COOKTOP/HOB

Place the cooktop into the cutout and tighten it with the supplied clamps. DO NOT OVER TIGHTEN.

The clamps will cope with bench thickness 15-50mm (see diagram) when used in the two orientations.

Image 2
Contents Current Information Important InformationBefore YOU Start Part No DCutout Dimensions DimensionsClearancesProduct Dimensions Clamping Down the COOKTOP/HOBGas Supply Before you call for service or assistance Adjusting the Cooktop Customer SupportMinimum Setting or Turn Down Conversion to Different GAS Type