Fisher & Paykel CG365D installation instructions Safety and Warnings, Electrical shock hazard

Page 2

1SAFETY AND WARNINGS

WARNING!

Electrical shock hazard

Disconnect product from the mains power supply before servicing. This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded power outlet. Do not under any circumstances cut or remove the grounding prong from this plug.

Failure to follow this advice may result in electrical shock or death.

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

IMPORTANT SAFETY INSTRUCTIONS!

This appliance shall be installed in accordance with the installation requirements of the local gas authority or the appropriate installation code or in the absence of local codes with the latest National Fuel Gas Code NFPA 54/ANSI Z223.1 or CAN/CSA B149.1,2 (Canada). Local building and electrical codes must be adhered to.

Electrical installation must be in accordance with the National Electrical Code, ANSI/NFPA70 - latest edition or CSA C22.1 (Canada) and/or local codes.

Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NFPA 225, or with local codes where applicable. Installation in Recreational Park Trailers: installation must conform with state or other codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5.

Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

Flexible appliance connectors shall meet the requirements of ANSI Z21.24 and State Boards. They shall not exceed 35 ½ inches (900 mm) in length. In order to avoid hazard, these appliances must be installed according to these instructions.

This appliance must be installed by an authorized person (Warning: this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts).

Please make this information available to the person installing the appliance as it could reduce your installation costs.

Please leave these instructions with the appliance. Inform the customer to retain for future reference and for the local inspectors’ use.

Failure to install the appliance correctly could invalidate any warranty or liability claims. Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Only genuine replacement parts may be used for servicing the appliance. These are available from your nearest Fisher & Paykel Service Center.

Before you install the appliance, please make sure that

the local distribution conditions (nature of gas and pressure) and the adjustment of the appliance are compatible. For adjustment conditions for this appliance, see ‘Gas rate summary’ under step 3. a suitable isolating switch is incorporated in the fixed wiring in an acceptable position.

the appliance is connected to a power outlet that is electrically grounded in accordance with local codes or in the absence of local codes, with the National Electric Code ANSI/NFPA 70 or CSA C22.2 (Canada).

there is a power outlet (110-120V 60Hz) within reach of the appliance cable (35 1/2” (900 mm) from the center rear of the appliance). This must be accessible after installation. The mains power supply cable should not touch any metal parts.

the countertop is square and level and no structural members interfere with space requirements the countertop is made of heat-resistant material.

you take note of the following recommended non-combustible materials: ¼” (6 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 1/32” (0.4 mm) stainless steel,

1/32” (0.6 mm) aluminum or 1/32” (0.5 mm) copper. the gas shut-off valve is accessible after installation.

if the power supply cable is damaged, it is replaced only by the special cable: Part no. 531954 – Flex Terminal Block Assy US, obtainable from authorized Fisher & Paykel Service Agents.

Image 2
Contents Installation Instructions Safety and Warnings Electrical shock hazardParts Supplied GAS Rate SummaryProduct & Cabinetry Dimensions Product and cabinetry dimensions inches mmClearance Dimensions Clearance dimensions mmDiscard Packaging Lower Gently Into the CutoutSecure to Countertop GAS Connection Connect to GAS SupplyLeak Testing Test Operation Final Checklist To be Completed by the InstallerInstructions D’INSTALLATION Consignes DE Sécurité ET Mises EN Garde Mise EN GardePièces Fournies Tableau DE Débit DES GAZDimensions DU Produit ET DES Armoires Dimensions du produit et des armoires pouces mmDimensions DE Dégagement Dimensions de dégagement mmAppliquez L’ISOLANT Adhésif Autour DU Rebord Installez LE Coude ET LA RondelleMettez L’EMBALLAGE AU Rebut Déposez L’APPAREIL Doucement Dans L’OUVERTUREFixez L’APPAREIL AU Comptoir Raccordement DU GAZ Raccordez À L’ALIMENTATION EN GAZ14 Vérification DES Fuites Faites UN Essai Être Remplie PAR L’INSTALLATEUR Liste DE Vérification Finale
Related manuals
Manual 60 pages 58.11 Kb

CG365D specifications

The Fisher & Paykel CG365D is a premier gas cooktop that embodies innovation and precision in culinary design. With its sleek and modern aesthetic, it seamlessly fits into any contemporary kitchen while offering exceptional performance. This cooktop is a popular choice among home chefs who value both functionality and style.

One of the key features of the CG365D is its robust design, which includes five burners crafted from high-grade stainless steel. This material not only enhances durability but also provides an easy-to-clean surface that maintains its shine over time. The cooktop is available in a classic stainless steel finish, adding a touch of elegance to your kitchen space.

The burners offer a range of power outputs, catering to various cooking needs. The dual flame wok burner is a standout feature, capable of delivering intense heat while offering precise control. This makes it ideal for stir-frying, deep-frying, and quickly boiling water, ensuring your meals are cooked to perfection every time.

Equipped with intuitive dial controls, the CG365D allows for effortless adjustments to heat levels. Each burner features a unique flame-failure safety device, ensuring a safe cooking experience by automatically shutting off the gas supply if the flame goes out. This safety feature provides peace of mind, especially in bustling kitchen environments.

Another remarkable technology integrated into this cooktop is the easy-to-remove, dishwasher-safe trivets. These cast iron components are designed to provide excellent heat retention while ensuring that you can easily clean and maintain the cooking surface. Additionally, the cooktop's design includes a continuous surface that allows for seamless movement of pots and pans from burner to burner.

The Fisher & Paykel CG365D also features a minimalist design with hidden controls, which reduces clutter and enhances the overall look of your kitchen. The precision cooking allows for better heat distribution, promoting even cooking regardless of the dish you’re preparing.

In summary, the Fisher & Paykel CG365D gas cooktop is built for those who appreciate quality, safety, and style. With its powerful burners, innovative technologies, and elegant design, it stands out as a premier choice for modern kitchens. This cooktop not only meets the demands of serious chefs but also elevates the culinary experience with its user-friendly features and thoughtful design. Whether you are simmering sauces or searing meats, the CG365D ensures that you can cook with confidence and finesse.