Fisher & Paykel CG905 installation instructions Before you start, Ventilation requirements

Page 10

8

Installation instructions

Before you start

Before starting to install the cooktop, make sure that:

the cooktop has not been damaged during transport. In case of doubt after unpacking and checking it, contact the retailer

the local distribution conditions (nature of gas and pressure) and the adjustment of the cooktop (as detailed on the appliance data label and in section ‘Gas supply and gas rate summary’ further below) are compatible

the installation will comply with the relevant ventilation and electrical requirements detailed further below

there is an earthed power outlet within the reach of the cooktop’s power supply cable (within 900 mm from the rear right of the cooktop, see dimension E in ‘Clearances’)

the power outlet will be accessible after installation

the power supply cable will not touch any hot metal parts the benchtop is made of a heat-resistant material

exposed bare edges of the cutout are sealed with an oil-based paint or moisture-proof polyurethane to prevent possible damage from moisture creeping between the cooktop trim and the benchtop.

Ventilation requirements

The installer must refer to the current local regulations.

For the United Kingdom and the Republic of Ireland only:

Important!

Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent. Some rooms require permanent ventilation in addition to the openable window, as detailed below.

The appliance should NOT be installed in a bed-sitting room of volume less than 20 m3.

The appliance should be installed in a room or space with an air supply in accordance with BS 5440:2 2000.

For rooms with a volume of less than 5 m3, permanent ventilation through a free area of at least 100 cm2 will be required.

For rooms with a volume between 5 m3 and 10 m3, permanent ventilation through a free area of at least 50 cm2 will be required, unless the room has a door which opens directly to the outside air, in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m3, no permanent ventilation is required.

Where there are other fuel-burning appliances in the same room, BS 5440-2: 2000 should be consulted to determine the correct amount of free area ventilation requirements.

The above requirements also allow for use of a gas oven and grill, but you need to consult a qualified engineer if there are other gas-burning appliances in the same room.

Image 10
Contents Installation instructions Page Contents Safety and warnings InstallationImportant safety instructions Operation Important safety instructions Installation instructions Cooktop and cutout dimensions mmInstallation instructions Ventilation requirements Before you startFor the United Kingdom and the Republic of Ireland only Electrical connection requirements Connecting the cooktop to the gas supply Fastening the cooktop to the benchGas connection with a flexible hose Special requirements for CG604DWFC and CG905DWFC modelsFor LPG G30 G31 BS 21/ISO 7-1 R 1/2 Fibre washer Checking the connections for leaks Leak-testing and flame-testing the cooktopChecking the burner flames Converting to a different gas type CG905DWAC onlyAdjusting the minimum burner setting 3b For LPG G30 G31CG905DWAC Final checklist To be Completed by the InstallerIntroduction Before using your new cooktopAbout your new cooktop Control dials Using your cooktopUsing the burners Models with auto-reignition CG905DWACIf a burner does not light If the flame is irregularIf the flame is accidentally extinguished If there is a power failureModels with flame failure protectionCG905DWFC, CG604DWFC Cookware Cooking guidelines and cookwareCooking guidelines Semi-rapidUsing a wok General advice Care and cleaningDetergent Care and cleaning CG905 models Replacing the pan supports correctlyCG604 models Replacing the burner parts correctly Semi-rapid, rapid, and auxiliary burnersBrass wok burner CG905DWAC models only Flames are yellow or hard to start One of my burners has an uneven flameThere is a power failure TroubleshootingFlame has accidentally been extinguished Before you call for service or assistance Warranty and serviceProduct details Page Page GB IE
Related manuals
Manual 32 pages 13.04 Kb Manual 32 pages 15.41 Kb

CG905 specifications

Fisher & Paykel CG905 is a modern gas cooktop that embodies a blend of innovative technology and classic craftsmanship. This cooktop is designed for both professional chefs and home cooks, meeting the higher demands of culinary enthusiasts. One of the standout features of the CG905 is its powerful gas burners. It boasts five burners, including a powerful 5.4kW single wok burner that is perfect for high-temperature cooking. The precision of heat control allows for a range of cooking styles, from quick simmering to rapid boiling.

Aesthetic appeal is also a strong suit of the CG905. Its sleek, stainless-steel finish not only enhances the look of your kitchen but also ensures durability and easy cleaning. The cooktop features a minimalist design that fits well in various kitchen layouts, providing a contemporary feel while being functional. The ergonomic knob controls are strategically placed for easy access and are designed for precise adjustments, making it easier to switch from high to low heat quickly.

The CG905 incorporates a unique technology known as the Exact Flame feature, which ensures that the flame remains steady at any setting. This contributes significantly to cooking precision, allowing users to achieve perfect results with every meal. Additionally, the cooktop is equipped with a flame failure device, providing an essential safety feature that automatically turns off the gas supply if the flame goes out.

Cleaning the Fisher & Paykel CG905 is made convenient with its removable burner caps and enamel trivets, which can easily be cleaned in the dishwasher. The minimalist design reduces the number of crevices and seams where food debris can hide, making maintenance an easier task.

The CG905 also offers flexibility in installation thanks to its ability to be flush-mounted, which creates a seamless look and integrates beautifully with the kitchen countertop. Furthermore, its gas connection allows for consistent performance and reliability associated with professional-grade cooking appliances.

In summary, the Fisher & Paykel CG905 gas cooktop stands out with its robust performance, sophisticated design, and advanced safety features, making it an optimal choice for anyone looking to elevate their cooking experience at home. With its combination of technology and style, it is an investment that will not only enhance culinary capabilities but also complement the overall aesthetics of any modern kitchen.