GE PSB42LSR dimensions Installation Space, Side Panels, Flooring, Grounding the Refrigerator

Page 2

PSB42LSR – GE Profile42" Built-In Stainless Side-By-Side Refrigerator with Electronic Dispenser

The Installation Space

*The finished cutout width must be: 41-1/2" for 42" models

Water and Electrical Locations

The opening must be prepared with the electrical and water supply located as shown.

The cutout depth must be 24"

The refrigerator will project forward, slightly beyond adjacent cabinets, depending on your installation.

Additional Specifications

A 120 volt, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.

Water line can enter the opening through the floor or rear wall. The water line installed should be 1/4" O.D. copper tubing or GE SmartConnecttubing between the cold water line and water connection location. The line should be long enough to extend to the front of the refrigerator. Installation of an easily accessible shutoff valve in the water line

is required.

Specification Revised 1/06

Side Panels

Side panels (not supplied) must be used whenever the sides of the refrigerator will be exposed.

*Depending on installation height.

Flooring

For proper installation, this refrigerator must be placed on a level surface of hard material that is at the same height as the rest of the flooring. This surface should be strong enough to support a fully loaded refrigerator, or approximately 1500 lbs.

NOTE: Protect the finish of the flooring. Cut a large section of the cardboard carton and place under the refrigerator where you are working.

Listed by

Underwriters

Laboratories

Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.

Grounding the Refrigerator

important—Please read carefully

for personal safety, this appliance must be properly grounded.

The power supply cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

do not use an adapter plug to connect the refrigerator to a 2-prong outlet.

do not use an extension cord with this appliance.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

210319

Image 2
Contents From Floor to 25-3/8 Case DepthCase Width 81-3/4 At Rear Top FrameFlooring Installation SpaceSide Panels Grounding the RefrigeratorFeatures and Benefits