GE GTS12BBPLCC Transfer Bottom Hinge to the Left, Transfer Fresh Food Door Stop to the Left

Page 11
Plug button

Installation Instructions

4TRANSFER BOTTOM HINGE TO THE LEFT

To access the bottom hinge, move the refrigerator so it is 30from a wall. Then carefully tip the refrigerator back until it rests against the wall.

CAUTION: Be sure that the coils

on the back of the refrigerator do not rest against the wall. Doing so could damage the coils.

30

Remove the screws (some models have washers with each screw), leveling leg and bottom hinge from the right side. Remove the leveling leg from the left side

6TRANSFER FRESH FOOD DOOR STOP TO THE LEFT

Remove the door stop from the bottom of the right side of the door. Transfer the plug buttons from the bottom left side to the right side, if applicable.

Install the door stop on the left side.

NOTE: The door stop appearance may vary by model. Always face the flange toward the front of the door.

 

 

Flange

 

Plug

 

 

Plug

button

 

 

Front of door

Front of door

button

location

 

 

 

location

7ATTACH FRESH FOOD DOOR HANDLE TO THE RIGHT

of the cabinet and install it in the right side.

Reassemble the bottom hinge on the left side.

NOTE: The leveling legs are not interchangeable.

5REMOVE FRESH FOOD DOOR HANDLE FROM THE LEFT SIDE

For models with handles: Remove the front plug button by carefully prying under the edge with a putty knife. Remove the exposed screw holding the handle.

Remove the two screws holding the handle to the top of the door.

On models with filler blocks, handle must be pulled straight out away from the door to remove.

Plug

Pull

straight

button

out

 

Handle bottom

Handle top

If applicable, remove the plug button from the left edge of the door and insert it into the hole on the opposite side.

For models without handles, skip to Step 9.

A. Models with plug buttons: Remove the plug buttons from the right edge of the door top and insert them into the handle screw holes on the left side.

Carefully remove the button on the door by prying under the edge with a putty knife and transfer to the opposite side.

Install handle: Install the handle on the other side of the door.

Screws for handle holes

Plug button

11

Image 11
Contents Refrigerators Before You Throw Away Your Old Refrigerator or Freezer Operating Instructions InstallationConsumer Support Troubleshooting Tips Operating Instructions HOW to Connect ElectricityAbout the storage drawer Instructions Safety InstructionsInstallation Instructions About the control on the refrigeratorWater Supply Kits Model 12 only About ice serviceIcemaker Accessory Kit Model 12 only Ice TraysCleaning the Outside Care and cleaning of the refrigeratorInstallation Instructions Tips Consumer Support TroubleshootingPreparing for Vacation SafetyInstructions Operating Replacing the Light BulbLeveling Legs Refrigerator LocationClearances Remove the Freezer Door Important NotesTools YOU will Need Tape the door shut with masking tape Remove the Fresh Food DoorTransfer TOP Hinge to the Left Transfer Fresh Food Door Stop to the Left Install the door stop on the left sideTransfer Bottom Hinge to the Left Attach Freezer Door Handle to the Right Remove Freezer Door Handle from the LeftTransfer Freezer Door Stop to the Left Align the Doors Install Center Hinge on the LeftRehang the Fresh Food Door Rehang the Freezer DoorAmount of food is added to the refrigerator or freezer Operating Instructions Safety Instructions InstallationCorrect temperatures Normal operating soundsSafety Instructions Operating Instructions Installation Before you call for service…ge.comBefore you call for service… GE Service Protection Plus We’ll Cover Any Appliance. Anywhere AnytimeConsumer Product Ownership Registration What GE Will Not Cover Safety Instructions Operating InstructionsTroubleshooting GE Will ReplaceReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

GTS12BBPLCC specifications

The GE GTS12BBPLCC is an advanced gas turbine designed for power generation applications, renowned for its efficiency and reliability. As part of General Electric’s family of gas turbines, the GTS12BBPLCC promises enhanced performance and operational flexibility, making it an attractive option for both utility and industrial settings.

One of the main features of the GTS12BBPLCC is its combined cycle capability, which allows operators to achieve higher efficiencies by utilizing both gas and steam turbines. This configuration can significantly reduce fuel consumption and greenhouse gas emissions, contributing to a more sustainable energy generation process. The turbine operates in a simple cycle mode as well, providing flexibility based on operational demands.

The GTS12BBPLCC incorporates advanced aerodynamics and materials that contribute to its superior performance. The turbine blades are designed using state-of-the-art computational fluid dynamics (CFD), which optimizes airflow and enhances combustion efficiency. Additionally, the use of advanced nickel-based superalloys ensures that the turbine can withstand the high-temperature conditions typical in gas turbines, enhancing durability and service life.

Another important characteristic of the GTS12BBPLCC is its quick start-up capability. Operators can bring the turbine online rapidly, which is critical in meeting sudden increases in electricity demand. This feature is particularly useful in markets with variable renewable energy sources, as it allows for seamless integration and grid stability.

The control system of the GTS12BBPLCC is equipped with GE’s latest digital technologies, including advanced monitoring and diagnostic capabilities. Operators have access to real-time data on turbine performance, enabling proactive maintenance and reducing unplanned outages. This digital edge enhances operational reliability and optimizes maintenance schedules.

Designed with operational flexibility in mind, the GTS12BBPLCC can efficiently utilize a variety of fuels, including natural gas and liquefied petroleum gas, further enhancing its versatility. This adaptability makes it suitable for diverse operational environments, from peaking power plants to baseload operations.

In summary, the GE GTS12BBPLCC stands out as a leading solution in the gas turbine market due to its combined cycle capability, advanced materials, quick start-up features, and digital monitoring technologies. Its ability to operate efficiently and flexibly makes it an ideal choice for modern power generation needs, paving the way for cleaner and more reliable energy production.