Sharp AC880 system manual Troubleshooting Fill Cylinder Procedure

Page 19

TROUBLESHOOTING FILL CYLINDER PROCEDURE

1)The cylinder of new refrigerant should be at ambient temperature or greater for best performance of the Fill Cylinder procedure. Make sure the cylinder was not recently moved from an air-conditioned storage room to a warm work area. Place the cylinder on a block of wood if necessary to elevate it from a cool concrete floor. Application of a heat belt to the cylinder will greatly enhance the speed.

2)Verify that the cylinder of new refrigerant (14) is up-side-down as shown in the figure on page 4 and that the cylinder valve is open.

3)If filling the Charge Cylinder from a DOT Cylinder, make sure the hose is connected to the liquid port and the DOT Cylinder is right-side-up.

4)If the yellow hose (15) was connected to the Fill Port (13) the first time the AC880 was used, there may be excessive air in the AC880 Charge Cylinder. At least 4 lbs. of refrigerant must be recovered/recycled into the AC880 Charge Cylinder following the Recover/Recycle procedure on Page 6. During this process, the air in the AC880 Charge Cylinder will be automatically purged.

5)Verify that the cylinder of new refrigerant has liquid refrigerant in it by shaking the cylinder or weighing the contents. A minimum of 4 lbs. of liquid is required.

6) Verify that the Yellow Hose (15) is connected correctly from the Cylinder (14) to the Fill Port (13). On an R12 AC880, the Fill Port is equipped with a valve core so a depressor must be present in the hose end (see figure). The Yellow Hose (15) has a shut-off valve on one end (instead of an anti-blowback valve) which must be connected to the Fill Port (13). The depressor in the hose may be adjustable, so extend the depth of the depressor by using needle-nose pliers.

7) Remove the valve core from the Fill Port (13) using a valve core remover.

There may be a machine fault if the above steps do not result in a successful increase of weight shown on the display after running the Fill Cylinder procedure for a minimum of 15 minutes.

Contact RTI Technical Support at 800-468-2321 (Ext.259) for help.

Page 18

Image 19
Contents AC880 Table of Contents Safety Precautions Before Using the AC880Using the AC880 Setup T O C H a R G E Fill Charge CylinderS E S RECOVER/RECYCLEDrain Recovered OIL Deep Vacuum T E R C H a R G E ChargeAutomatic M P O F F M I N Enter Access Stored DataSET Over Charge Amount Filter Maintenance Scheduled MaintenanceDescription Parts IdentificationParts Identification Parts Identification Troubleshooting Fill Cylinder Procedure

AC880 specifications

The Sharp AC880 is a state-of-the-art air conditioning unit designed to provide optimal comfort in residential and small commercial spaces. With its sleek and modern design, it not only enhances the aesthetic appeal of any room but also incorporates advanced technologies to ensure efficient cooling and heating performance.

One of the standout features of the Sharp AC880 is its powerful cooling capability. Equipped with a high-efficiency compressor, this unit can quickly lower the room temperature, making it ideal for hot summer days. Additionally, its energy-efficient design helps reduce electricity consumption, making it an eco-friendly choice for consumers. The AC880 boasts an impressive EER (Energy Efficiency Ratio), ensuring that users receive the best cooling output for their energy investment.

The AC880 is also equipped with Sharp's patented Plasmacluster Technology, which utilizes positive and negative ions to neutralize airborne pollutants, allergens, and odors. This advanced filtration system not only purifies the air, enhancing indoor air quality, but also contributes to a healthier living environment. The Plasmacluster technology works quietly in the background, providing added comfort without disturbing your daily activities.

For added convenience, the Sharp AC880 features a user-friendly remote control that allows you to adjust temperature settings, fan speeds, and mode selections from across the room. The intuitive control panel can also be accessed directly on the unit, offering multiple options to customize your comfort level. The programmable timer function allows users to set the unit to turn on or off at specific times, reducing energy waste and ensuring that your space is always at the desired temperature when you return home.

Another significant characteristic of the AC880 is its quiet operation. Designed for low noise levels, this air conditioner ensures that you can enjoy a cool environment without the distraction of loud machinery. This makes it ideal for bedrooms and workplaces, where a peaceful atmosphere is essential.

In summary, the Sharp AC880 is a versatile air conditioning unit that combines efficiency, advanced technology, and user-friendly features. With its powerful cooling, air purification technology, and smart controls, it stands out as a top choice for anyone looking to enhance their indoor comfort. Whether you are dealing with sweltering heat or chilly evenings, the Sharp AC880 is a reliable solution that meets modern cooling needs while prioritizing environmental sustainability and user comfort.