2.52"
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 38.98" |
|
| ||
44.98" |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6.00"
47.92" |
|
1.58" | 1.82" |
|
The "Advanced Closed System" offers the following advantages:
■Saves energy
■Automatic moisture level adjustment
■Low heat and steam emission to the kitchen
■Automatically regulated steam injection
■Enables immediate change into the steam mode
■"Crisp & Tasty" demoisturizing function
Model:OEB-10.20
Pan Capacity [Unit has 11 slide rails at 2.64" (67mm) apart]:
11 | (20" x 26") full size wire racks | 11 | (18" x 26") full size sheet pans - on wire racks |
22 | (13" x 18") half size sheet pans - on wire racks | 20 | (12" x 20" x 2 1/2") steam table pans |
22 | (12" x 20" x 1") steam table pans | 20 | (12" x 20") frying baskets - (no wire racks needed) |
|
|
|
|
FRONT VIEW
3.39"
For Banquet Operations: Optional Plate Rack holds 63 plates
Unit Dimensions: Width - 52.26", Depth - 43.24", Height - 45.68"
Shipping Dimensions: Width - 58", Depth - 49", Height - 54"
13.07"
40.44"
2.80"
2.80"
AV
S |
TOP VIEW
(including packaging)
Shipping Weight: | 540 Lbs |
Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"
•Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
•Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
•Installation must comply with all local fire and health codes.
Agency Approvals: | UL, UL - Sanitation (NSF Standards) |
| ||
Electrical Requirements: | 208/3/60 | 240/3/60 | 440/3/60 | 480/3/60 |
Total Connected Load: | 26.3 KW | 34.9 KW | 29.4 KW | 34.9 KW |
Hot Air: | 25.8 KW | 34.3 KW | 28.8 KW | 34.3 KW |
12.68"
31.50"
Steam Generator: | 20.5 KW | 27.3 KW | 22.9 KW | 27.3 KW |
Amps per Phase: | 77.8 | 88.8 | 41.4 | 44.9 |
Do not connect to a G.F.I. outlet |
|
|
| |
|
|
| ||
Water Connections: | Cold Water (drinking water quality) |
| ||
Flow Pressure: | 30 - 60 PSI |
|
|
|
Water Inlets: | 3/4" |
|
| 3.23" | 41.42" |
| 3.27" |
| W1 | Treated Water for Steam Generator |
|
|
|
|
|
| |||
|
|
|
|
| 6.93" |
| W2 Untreated Water for Condenser and Hand Shower | |
|
| 14.26" |
|
|
|
|
| |
| 21.19" |
|
|
| D | Drain Connection: | 2" Tube | |
27.29" |
|
|
|
| Venting: | Exhaust Hood required | ||
| D | 29.61" |
| AV | Air Vent | |||
| 2.96" |
|
|
| ||||
|
|
|
|
| ||||
|
|
|
|
| CS | *Connection for Cleaning Solution | ||
|
|
|
| W1 |
| |||
|
|
|
|
|
|
|
| |
1.19" | RC |
|
| W2 |
| RC | *Connection for Rinse Cycle |
|
|
|
|
|
|
| |||
|
|
| 3.90" | S |
|
| ||
|
|
|
|
| Low Pressure Safety Valve |
| ||
| CS |
|
|
|
|
|
|
|
3.00" |
|
|
|
|
|
| BOTTOM VIEW | *Available as an option |
|
|
|
|
|
| |||
4.97" |
|
|
|
|
|
|
|
|
|
| 10.87" |
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.
SECT. IIA PAGE 10 0108