Briggs & Stratton 030222 owner manual Using the Generator, System Ground, Generator Location

Page 8

PowerBOSS™

5000W Portable Generator

OPERATION

 

 

 

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Generator Clearance

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 3). Prevailing winds and air currents should be taken into consideration when positioning generator.

Figure 3 — Generator Clearance

Typical Generator Shown

Exhaust Port

8

Image 8
Contents Model / Modelo 030222 5000W Equipment Description Table of ContentsSafety Rules When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Install Wheel KITCarton Contents Remove Generator From CartonWhen Adding Fuel Before Starting EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Stopping the EngineVolt AC, 15 Amp Duplex Receptacle ReceptaclesVolt AC, 20 Amp, Duplex Receptacles Power Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceEngine Storage Other Storage Tips StorageGenerator Storage Troubleshooting Problem Cause CorrectionLimited Warranty Conserve Estas Instrucciones Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Tomacorriente Dobles de 120 Voltios AC, 20 Amp Conozca SU GeneradorTomacorriente Dobles de 120 Voltios AC, 15 Amp Montaje Instale EL Juego DE RuedasPara Retirar El Generador De La Caja Contenido de la CajaAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Tierra del SistemaUbicación del Generador Conexión al Sistema Eléctrico de un EdificioOperando EL Generador Precaución Encienda el MotorConexion De Cargas Electricas Parado Del MotorVoltios AC, 15 Amperios, Receptáculos Dobles Receptáculos PrecauciónVoltios AC, 20 Amperios, Receptáculos Dobles No Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorDiagnositicos DE Averías AlmacenamientoAlmacenando el Generador Almacenando el MotorGarantía Limitada

030222 specifications

Briggs & Stratton 030222 is a powerful and versatile portable generator designed to deliver reliable performance, making it an ideal choice for both home use and outdoor activities. With a robust design and advanced technology, this generator is built to handle a variety of situations, including emergency backup power, camping trips, and recreational activities.

One of the standout features of the Briggs & Stratton 030222 is its impressive power output. Equipped with a reliable engine, this generator can provide up to 2,500 watts of starting power and 2,000 watts of running power. This makes it capable of powering essential appliances such as refrigerators, lights, and more during an outage, ensuring that you remain comfortable and connected.

The generator features a durable frame that enhances its stability and longevity. It is built with high-quality components that withstand the rigors of transportation and variable weather conditions. Additionally, it includes built-in wheels and a handle for easy maneuverability, allowing users to effortlessly transport it to their desired location.

The Briggs & Stratton 030222 leverages advanced inverter technology, which not only delivers clean and stable power but also reduces noise levels, making it quieter than traditional generators. This is particularly beneficial for recreational use, where noise restrictions may apply. The inverter technology also ensures that sensitive electronic devices, such as laptops and phones, are protected from voltage spikes.

Another notable characteristic is its fuel efficiency. With an extended runtime, the generator can operate for hours on a single tank of gasoline, minimizing the need for frequent refueling. This feature is particularly advantageous during camping trips or long power outages.

Safety is also a priority in the design of the Briggs & Stratton 030222. It incorporates multiple safety features, including overload protection and low oil shutdown, which ensures that the engine does not sustain damage from running with insufficient oil. This adds an extra layer of reliability, giving users peace of mind during operation.

In summary, the Briggs & Stratton 030222 is an efficient and reliable portable generator that meets the power demands of various situations. With its strong power output, advanced inverter technology, fuel efficiency, and safety features, it stands as a solid choice for those in need of a dependable source of electricity, whether for home emergencies or outdoor adventures.