Liebert CLINAC 18R Standard Features, Optional Features, Optional Accessories, Required Options

Page 2

D

B

A

C

Model

A-Width

B-Height

C-Depth

D

Weight

Voltage (60 Hz)

No.

in. (mm)

in. (mm)

in. (mm)

lbs. (kg)

 

 

 

 

 

 

 

PS096A*

77 (1956)

69.25 (1759)

38.5 (978)

5.5 (140)

750 (340)

460, 3-phase; 208/230, 3-phase

 

 

 

 

 

 

 

PS120A*

77 (1956)

69.25 (1759)

38.5 (978)

5.5 (140)

750 (340)

460, 3-phase; 208/230, 3-phase

 

 

 

 

 

 

 

*Includes additional height due to storage tank.

Standard Features

Indoor/outdoor cabinet

Scroll compressor

Refrigerant dehydrator

Expansion valve

Refrigerant receiver

Stainless steel fluid reservoir expansion tank

Pressure relief valve

Hot gas bypass valve capacity control

Stainless steel pump

Optional Features

• Refrigerant gauges and reservoir heater

Optional Accessories

Emergency water bypass

Enviro-source emergency bypass

Water level control and alarm system

Fluid pressure gauge

Check valve

Dial thermometer

Relief valve

Circuit setter

Ball valve

High temperature thermostat

Low flow switch

Liebert RCM8 monitor

Required Options

100 gallon stainless steel storage tank built into chiller frame.

1050 Dearborn Drive

Via Leonardo Da Vinci 8

23/F Allied Kajima Bldg.

P.O. Box 29186

Zona Industriale Tognana

138 Gloucester Road

Columbus, OH 43229

35028 Piove Di Sacco

Wanchai

Phone: 800.877.9222

Italy

Hong Kong

Fax: 614.841.6022

Phone: 39.049.9719.111

Phone: 852.2.572.2201

 

Fax: 39.049.5841257

Fax: 852.2.572.1182

Liebert Web Site—http:www.liebert.com

SL-16563 (07/00)

©2000 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

®Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or regisered trademarks of their respective owners.

Process Fluid Chiller Designed for Varian CLINAC 18R, 1800, 2100C/D & 2300C/D

2

Image 2
Contents Clinac 18R, 1800, 2100C/D, 2300C/D Specifications Process Fluid Chiller SpecificationsOptional Accessories Standard FeaturesOptional Features Required Options

2300C/D, CLINAC 18R, 2100C/D, 1800 specifications

The Liebert 1800, 2100C/D, CLINAC 18R, and 2300C/D are advanced solutions in the realm of precision cooling and power management for IT and telecommunications infrastructure. These systems are designed to enhance operational efficiency, providing reliable performance under demanding conditions.

The Liebert 1800 series is known for its modular and scalable design, making it an ideal choice for data centers requiring flexibility in cooling capabilities. One of its key features is the use of dynamic cooling technology, which adjusts the cooling output based on real-time load requirements. This not only maximizes energy efficiency but also extends the lifespan of the equipment by preventing overheating.

The Liebert 2100C/D models further enhance this flexibility with advanced monitoring and control systems. These units come equipped with an intuitive interface that allows for remote management, giving operators comprehensive insight into system performance and environmental conditions. Features such as variable speed fans and digital scroll compressors contribute to significant energy savings, while multiple airflow configurations ensure optimal cooling distribution throughout the facility.

The CLINAC 18R stands out in the realm of medical and industrial applications. This system is specifically designed to provide superior cooling in radiation oncology, ensuring the precise temperature control necessary for sensitive equipment. It features advanced filtration technology, reducing airborne contaminants, which is crucial in healthcare environments. The CLINAC 18R also incorporates a fail-safe operation mode, ensuring continuous performance even in the event of a component failure.

The Liebert 2300C/D system takes resilience to the next level with its built-in redundancy and fault-tolerant design. These units are engineered to handle critical applications, providing uninterrupted cooling even under extreme conditions. The enhanced control algorithms optimize energy consumption while maintaining consistent temperature levels.

All of these Liebert solutions integrate seamlessly with existing infrastructure, showcasing compatibility with various monitoring platforms and building management systems. With a strong focus on sustainability and energy efficiency, these models help businesses reduce their carbon footprint while ensuring the stability of their operations. This combination of features makes the Liebert 1800, 2100C/D, CLINAC 18R, and 2300C/D an ideal choice for organizations looking to optimize their cooling and power management systems.