RTI ID900 manual VI. Specifications Sample Parameters, Detected Compounds, Sensor Technologies

Page 12

VI. Specifications

Sample Parameters:

Vapor only, oil and liquid free, 300 psig (2 MPa) Maximum

Detected Compounds:

R12, R134a, Air and unknown compounds

Sensor Technologies:

Non-Dispersive Infrared and Chemical Fuel Cell

Refrigerant Sample Size:

0.12 ounces (3.5 grams) per typical sample – weight of vapor loss

Power (Standard):

Powered by vehicle battery through clip-on adapter harness (10 to 14 VDC).

Power (Optional):

Powered by line power through plug-in wall adapter harness, 115 VAC unit (OPTIONAL) or 220 VAC unit (OPTIONAL)

Operational Temperature Range:

45-100oF (7-38oC)

Instrument Weight:

1.5 Lbs. (454 grams)

R12/R134a Purity Setpoint:

Pass if single refrigerant, R12 or R134a, is detected in concentrations equal to or greater than 98% by weight.

Unknown Refrigerant Purity Setpoint:

In the presence of detected unknown refrigerant types R12 or R134a is considered pure if detected in concentrations equal to or greater than 96% by weight.

Effect of Air Concentrations:

Air is not considered a contaminate and will be removed from the weight concentration determination of refrigerants. Air concentrations will only be reported for blends of R12 and R134a refrigerants.

SAE J1771:

If the refrigerant being tested is identified as contaminated, any visual percentages displayed of CFC-12 (R-12) or HFC-134a (R- 134a) outside the design certified value is informational and may not be accurate. SAE J1771 Certification Note: This equipment has not been designed certified for contaminate detection of R-124 or R-142B.

12

Image 12
Contents ID900 Table of Contents Page II. Functional Description Rear View III. Hardware DescriptionPower Harnesses Sample HosesIV. Operation Procedure Pre-Operative Inspection Operation ProcedurePost-Operation Procedure Maintenance Error Codes and Corrective Actions Corrective ActionsMaintenance Procedures Sample Filter Replacement Replacement ProcedureSample Hose Inspection and Cleaning Sample Hose Flushing ProcedureAir Detection Sensor Replacement Air Detection Sensor Replacement ProcedureSpare Parts Listing Spare Part Description Order Part NumberVI. Specifications Sample Parameters Power StandardPower Optional Operational Temperature Range