JBL SUB12 Test Set Up and Procedure, Venue SUB12, Equipment needed, Sweep Function

Page 9
SUB12 Test Set Up and Procedure

Venue SUB12

SUB12 Test Set Up and Procedure

Equipment needed:

Function/signal generator/sweep generator

Integrated Amplifier

Multimeter

Speaker cables

General Unit Function (UUT = Unit Under Test)

1)From the signal generator, connect line level (RCA) cables to the Subwoofer Line Level Input jacks L/R on the UUT. Use a Y-cable from a mono source if necessary to connect to both inputs.

2)Turn the CROSSOVER control to maximum (150).

3)Turn the LEVEL control on the UUT to completely counterclockwise (MIN).

4)Phase switch position = does not matter; LFE/Normal switch should be on NORMAL

5)Turn on generator; adjust to 150mV, 50 Hz.

6)Plug in UUT; turn the power switch ON. LED should switch from Red to Green.

7)Turn LEVEL control full clockwise (MAX); immediate and vigorous bass response should be heard and felt from port tube opening on the bottom.

8)Turn off generator, turn LEVEL control full counterclockwise (MIN), and disconnect RCA cable.

9)Connect one pair of speaker cables to Speaker Level input terminal (IN) on UUT. Cables should be connected to an integrated amplifier fed by the signal generator.

10)Turn on generator and adjust so that speaker level input at the amplifier is 3.3V, 50 Hz. Turn LEVEL control full clockwise (MAX).

11)Green LED should light; immediate and vigorous bass response should be heard and felt from the port tube opening.

Sweep Function

1)Follow steps 8-10 above, using a sweep generator as a signal source.

2)Sweep generator from 20Hz to 300Hz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or any other noises. If any unusual noises are heard, remove woofers and test.

Driver Function

1)Remove woofer from cabinet (instructions on exploded view drawing); detach + and - wire clips.

2)Check DC resistance of woofer; it should be 4.8 ohms ±10%

3)Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V.

4)Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.

8

Image 9
Contents SUB12 Venue SeriesAmplifier/Subwoofer CONTENTS BASIC SPECIFICATIONSVenue SUB12 150W Powered Sub/ Plate Amp Venue SUB12VENUE SUB12 QA Test Venue SUB12Parameter Conditions£Phase Switch CONTROLS AND CONNECTIONSPOWER PHASE 0ºSYSTEM CONNECTIONS Venue SUB12Power On MAINTENANCE AND SERVICEAdjust Gain Phase ControlVenue SUB12 SUB12 Test Set Up and ProcedureEquipment needed General Unit Function UUT = Unit Under TestVenue SUB12 Venue SUB12 Venue SUB12 SUB12 120V Electrical parts listPart number DescriptionPart number Venue SUB12Description Reference DesignatorPart number Venue SUB12Description Reference DesignatorVenue SUB12 Venue SUB12 Venue SUB12 音 律 電 子 股 份 有 限 公 司 Venue SUB12Venue SUB12