∙Turn the knob to minimum and make sure (with the door closed) that the flame became smaller, but stable (about 3 o 4 mm). If the flame is not stable on the minimum setting, remove the knob, unscrew the screw from the control panel and remove it. Turn the screw
“M” to adjust the thermostat minimum, turning it
c)The grill burners has no regulation of the minimum.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.
Check that the flame does not turn off when you turn the tap quickly from high to low.
Attention: on completion of the above operation, please replace the current technical data label with a new one containing details of the gas which the appliance has now been converted to. The new technical data label is contained in the nozzles Kit supplied with the cooker.
Note: should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.
Burner and nozzles characteristics
Table 2
|
|
|
|
|
| Liquid Gas |
|
| Natural Gas | |||
|
|
|
|
|
|
|
|
|
|
|
| |
Burner | Diameter | Thermal power | Nozzle |
| Flow* | Nozzle |
| Flow* | ||||
| (mm) |
| kW | 1/100 | 1/100 |
| 1/100 |
| ||||
|
|
| g/h |
| l/h | |||||||
|
| (p.c.s.*) | (mm) | (mm) |
| (mm) |
| |||||
|
|
|
|
|
|
| ||||||
|
| Nomin. |
| Reduc. |
|
| *** |
| ** |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
90 | 3.30 |
| 0.70 | 42 | 90 | 240 |
| 236 | 135 |
| 314 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
78 | 2.70 |
| 0.70 | 42 | 83 | 196 |
| 193 | 122 |
| 257 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
50 | 1.70 |
| 0.40 | 29 | 65 | 124 |
| 121 | 97 |
| 162 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
50 | 1.70 |
| 0.40 | 29 | 65 | 124 |
| 121 | 97 |
| 162 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
Oven | - | 3.35 |
| 1.20 | 53 | 90 | 244 |
| 239 | 135 |
| 319 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Grill | - | 2.20 |
| - | - | 78 | 160 |
| 157 | 117 |
| 209 |
|
|
|
|
|
|
|
|
|
|
|
| |
Supply | Nominal (mbar) | 37** |
|
|
| 20 | ||||||
Minimum (mbar) | 25** |
|
| 20*** |
| 17 | ||||||
pressures |
|
|
| |||||||||
Maximum (mbar) | 45** |
|
| 35*** |
| 25 | ||||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013
** | Propane | P.C.S. = 50,37 MJ/Kg |
*** | Butane | P.C.S. = 49,47 MJ/Kg |
| Natural | P.C.S. = 37,78 MJ/m3 |
|
|
|
|
| Technical characteristics |
|
|
|
Mains frequency and voltage of the electric section and characteristics of the gas section
Model |
| Gas section | Electric section |
| |
|
|
|
|
|
|
| Class |
| Rated power | Voltage | Power |
|
| kW (1) | (W) | ||
|
|
|
| ||
|
|
|
|
|
|
KG 6407 BG/G |
|
| 11,88 (864 g/h - G30) |
|
|
KG 6407 WG/G | II2H3+ |
| 19 | ||
| (848 g/h - G31) | ||||
KG 6407 XG/G |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).
6