Marvel Industries 61WCM manual Keypad Lockout Feature Loc

Page 5

OPERATION

Keypad Lockout Feature (Loc)

This feature is useful for prohibiting changes in the temperature set point or accidentally turning the unit off. Press and hold the “SET” key to display the cur- rent “Loc” setting. If “No” is displayed, Lockout is OFF and all keys are enabled. If “Yes” is displayed, Lockout is ON and the “ON/OFF”, “WARMER”, and “COLDER” keys are disabled. However, the key tones remain enabled. While holding the “SET” key, press the “WARMER” or “COLDER” key to select the desired state. Release the “SET” key to confirm the selection.

NOTE: The Information/Lockout Key “SET” remains enabled regardless of the “Loc” setting.

Warning Alarms

Your wine cellar has been fitted with a MicroSentry™ refrigeration monitor. This monitor will let you know if your cellar is not functioning properly for optimum wine storage.

Door Ajar Alarm

If the door has been left open for over five minutes, the alarm will sound in one second intervals. The display panel will flash “Do” and the LED light will be a steady amber color. This will stop as soon as the door is closed.

High and Low Temperature

If your unit reaches an unacceptable temperature out- side of your set point, the alarm will sound in one second intervals. The display panel will flash either “Hi” or “Lo” depending upon the condition and the LED light will be a steady amber color. “Hi” indicates that the temperature is 10 degrees F above the set point and “Lo” indicates that the temperature is 10 degrees F below the set point. These alarms will warn you that your wines have seen tempera- tures that may not be conducive for long term storage. The alarm will remain active until the condition is corrected.

NOTE: During initial appliance start-up, the high tem- perature alarm may sound until the interior temperature reaches set point.

Alarm Codes

The control monitors and stores select unit parameters and will display error codes with sound each time a fault is detected. See reference below for a description of each error code.

 

Error Code Detection Reference

 

 

 

Error Code

 

Description

 

 

 

Do

 

Door Open

 

 

 

Hi

 

High Temperature

 

 

 

Lo

 

Low Temperature

 

 

 

E1

 

Sensor Fault

 

 

 

CL

 

Condenser Coil Cleaning Recommended

 

 

 

Audible Alarm Mute

Press any key to mute the audible portion of an alarm condition. Alarm sound is only muted, not disabled. If the condition(s) that caused the alarm(s) continue, visual indication will continue and alarm sound will periodically

continue for 20 seconds every 60 minutes.

4

Image 5
Contents Marvel Wine Cellar Installation Operation and Maintenance InstructionsReminder Starting OUTExtension Cord InstallationOperation Keypad Lockout Feature Loc Appliance Features Care and Cleaning of Your Wine Cellar Problem Possible CAUSES/SOLUTIONS TroubleshootingObtaining Service Warranty Page 41010734 Rev. C

61WCM specifications

Marvel Industries has made waves in the industry with its latest innovation, the Marvel Industries 61WCM, a cutting-edge piece of equipment designed to meet the evolving demands of modern manufacturing and assembly processes. Boasting a host of impressive features, technologies, and characteristics, the 61WCM stands out as a benchmark for quality and efficiency.

At the heart of the 61WCM is its high-performance automation capabilities. This model incorporates advanced automation technology that streamlines operations, reducing human error and increasing throughput. It utilizes smart sensors and real-time data analytics to monitor performance and ensure optimal functioning at every stage of production, contributing significantly to overall operational efficiency.

One of the standout features of the 61WCM is its modular design, allowing for easy adaptation and scalability according to specific production needs. This flexibility is crucial for businesses looking to optimize their workflow without the burden of significant reconfiguration. The modular setup enables companies to add or remove components based on demand fluctuations, ensuring that they remain agile in the marketplace.

Additionally, the 61WCM is equipped with state-of-the-art safety mechanisms. The integration of safety protocols and user-friendly interfaces ensures that operators can engage with the machine confidently and safely. This commitment to safety not only protects workers but also minimises the risk of production downtime due to accidents.

Power efficiency is another hallmark of the Marvel Industries 61WCM. The machine incorporates energy-saving technologies that comply with the latest environmental regulations, thus helping businesses reduce their carbon footprint while also cutting operational costs. The emphasis on energy efficiency aligns with the industry’s push towards sustainability without sacrificing performance.

Furthermore, the 61WCM features advanced connectivity options, facilitating seamless integration with existing manufacturing systems. This connectivity plays a crucial role in enabling predictive maintenance, where potential issues are identified before they impact productivity, thus saving time and reducing costs associated with unexpected repairs.

In summary, the Marvel Industries 61WCM is a game-changer in the manufacturing sector. Its high-performance automation, modular design, robust safety features, energy efficiency, and advanced connectivity set it apart from competitors. With these characteristics, the 61WCM positions itself as a reliable choice for forward-thinking manufacturers looking to enhance their productivity and adapt to an ever-changing market landscape.