Remove plastic overwrap, banding and corrugation packaging. The wooden skid is removed by unscrewing
All merchandisers are tested, inspected and carefully packaged to ensure each unit arrives ready for operation. Please return postage paid warranty card to activate merchandiser warranty. (See back page of manual) Retain for future reference.
Note: Merchandiser should be moved close to an upright position. If merchandiser is tilted 45° past vertical, it is recommended the unit not be used for a time equal to the time it was not vertical. This will allow the compressor lubricant to return to level for designed operation.
The merchandiser installation location should have a solid level base. If merchandiser is not level, the self- closing doors on upright models may not close or seal properly. The installation location must also provide good air flow for designed refrigeration system operation. DO NOT block refrigeration grill openings. Grill blockage may result in compressor failure.
Outdoor merchandisers: Locations shaded from sunlight are recommended for more economical operation.
Indoor merchandisers: Locations must keep the area above and within full top cover clear from storage items or from obstructions. As per above, location must provide good air flow for designed refrigeration system.
1.Electrical: The electrical voltage and frequency cycle at installation site must coincide with merchandiser decal serial label. Electrical service connections must be in accordance with the National Electrical Code, state code and any local code that may apply. All merchandisers are wired to a polarized power cord with
CAUTION: Improper use or removal of the grounding plug can result in risk of electrical shock.
3