Bi-Amp Operation
The VX 12HP, VX 12Q, VX 12.2Q, VX 15HP, VX 15Q only may be internally reconfigured for
First, remove the rear termination panel. It is secured with 2.5 mm hex drive screws.
In passive (default) mode, the internal wiring is as shown in Fig. 1, with the
Fig. 1.
For
Fig. 2.
For
speakON | Amplifier | |
1 | + | LF + |
1 | - | LF – |
2 | + | HF + |
2 | - | HF – |
Rigging and Safety Procedures
Tannoy Professional loudspeakers should be installed only by fully qualified installers using dedicated Tannoy hardware, in accordance with all the required safety codes and standards that are applied at the place of installation.
WARNING: As the legal requirements for flying/suspending/hanging/ rigging loudspeakers change from country to country, please consult your local safety standards office before installing any product. We also recommend that you thoroughly check any laws and bylaws prior to installation. For more detailed information on rigging hardware and safety procedures, please consult the full VX Series and VXP Series Hardware Manual available at www.tannoy.com.
Note that the barrier strip terminals are wired for passive