At least 25 mm
From the side |
Mains Connection.
Check that the voltage stated on the data plate is the same as the mains voltage in use.
Plug the refrigerator power cord into an easily accessible earthed wall socket.
Electrical leads must be routed and secured so that they cannot come into contact with hot or sharp parts of the refrigerator.
Wall |
25 |
Rear | 25 | From | |
above | |||
|
25 |
Wall |
The gas installation and servicing should only be carried out by an authorized, qualified person and must conform to all relevant national and local regulations.
The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 30 mbar.
A
If a hose connection is used, only tubing of the approved type must be used. The length of the tube shall not exceed 1,5 m.
The gas inlet tube should be connected at the rear to the connection provided and be well secured with hose clamps.
All completed connections should be checked for leaks with soapy water.
DO NOT use a flame to check for gas leaks.
ELECTRICAL CONNECTION
The electrical installation must be carried out in a proper and durable manner, taking into accounts all relevant regulations and codes of practice.
For mains voltage operation, it is important that the circuit is effectively earthed.