Instructions for the installer
4.4Regulation of primary air
Referred to distance “X” in mm.
Burner |
|
| NG |
| LPG |
|
|
| 1.0 kPa |
| 2.75 kPa |
|
|
|
|
|
|
|
|
|
| ||
Auxiliary |
|
| 3.0 |
| 2.5 |
|
|
| |||
Semi rapid |
| 3.0 |
| 2.0 | |
|
|
| |||
Rapid |
| 3.0 |
| 2.0 | |
|
|
| |||
Wok |
| 4.0 |
| 2.5 |
5. FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “4.1 Removing the top”.
5.1Adjustment of minimum for natural gas
Light the burner and take it to the minimum. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
13