Smeg PVA96 Final Operations, Regulation of primary air, Adjustment of minimum for natural gas

Page 11

Instructions for the installer

4.4Regulation of primary air

Referred to distance “X” in mm.

Burner

 

 

NG

 

LPG

 

 

 

1.0 kPa

 

2.75 kPa

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

3.0

 

2.5

 

 

 

Semi rapid

 

3.0

 

2.0

 

 

 

Rapid

 

3.0

 

2.0

 

 

 

Wok

 

4.0

 

2.5

5. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “4.1 Removing the top”.

5.1Adjustment of minimum for natural gas

Light the burner and take it to the minimum. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

13

Image 11
Contents Contents Instructions for Safe and Proper USE IntroductionIntroduction Electrical connection Instructions for the installerInstallation of the Appliance PositioningDischarge of combustion products GAS Connection Extract from AGA601 Requirements Removing the top Adapting to Different Types of GASRegulation for LPG Adjustment for natural gasRegulation of primary air Adjustment of minimum for natural gasFinal Operations Lubrication of gas taps Arrangement of burners on the hobLighting the burners Instructions for the userUSE of the HOB Burner knobDiameter of containers Practical advice for using the burnersCleaning of the hob components Cleaning and MaintenanceCleaning stainless steel Preventive maintenance Problem Cause Problems and CausesCod