Instructions for the Installer
U.S. INSTALLATION ONLY – 3-WIRE GROUNDED JUNCTION BOX
Refer to picture 1, where local codes allow the connection of the oven frame grounding conductor to the power supply cable neutral wire (white wire):
- The ground wire must be connected first;
- If local codes permit, connect the green or
- Connect the red and black wires of the appliance cable to the matching power supply cables in the junction box.
UL/CSA listed wire connector
pic.1)
U.S. INSTALLATION AND CANADIAN INSTALLATION –
-Separate the green or
-The ground wire must be connected first;
-Connect the green or
-Connect the red and black wires of the appliance cable to the matching color wires in the junction box.
UL/CSA listed wire connector
pic.2)
-Connect the white wire from the appliance cable to the neutral (white) wire in the junction box.
Connect to a 20A fuse or circuit breaker. Connect to copper wire, or, if connection is made to aluminum house wiring, use