–not be installed next to radiators, cookers or other sources of heat;
–only be installed at a location whose ambient temperature corresponds to the climate classification, for which the appliance is designed.
The climate classification can be found on the serial plate, which is located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for each climate classification: each climate classification:
Climate classification |
| for an ambient temperature of |
|
|
|
|
|
|
SN |
| +10 bis +32 °C |
|
|
|
N |
| +16 bis +32 °C |
|
|
|
ST |
| +18 bis +38 °C |
|
|
|
T |
| +18 bis +43 °C |
|
|
|
If installation next to a source of heat is unavoidable, the following mini- mum clearances must be maintained at the sides of the appliance:
–for electric cookers 3 cm;
–for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is required between the cooker and the refrigeration appliance.
If the refrigeration appliance is installed next to another refrigerator or free- zer a clearance of 5 cm at the sides is required, in order to prevent the for- mation of condensation on the outside of the appliance.
Your appliance needs air
For safety reasons, minimum ventila- tionmust be as shown Fig.
Attention: keep ventilation ope- nings clear of obstruction;
mm100
mm10 NP00
10 mm |
33