Whirlpool KDSS907X dimensions Product Model Numbers, GAS Supply Requirements Product Dimensions

Page 1

® 30" Freestanding and Slide-In Dual Fuel Range

PRODUCT MODEL NUMBERS

KDRS807S KDSS907S

KDRS807X KDSS907X

GAS SUPPLY REQUIREMENTS

PRODUCT DIMENSIONS

Freestanding Range

Slide-in Range

Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. If local codes permit, a new CSA design-certified, 4 ft - 5 ft (122 -

152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D.,

flexible metal appliance connector may be used for

connecting range to the gas supply line. A ¹⁄₂"

(1.3 cm) male pipe thread is needed for connection

to the female pipe threads of the inlet to the

appliance pressure regulator. The supply line must

be equipped with a manual shutoff valve. This valve

30"

(76.2 cm)

5³⁄₄"

(14.6 cm)

36" (91.4 cm) cooktop trim height with leveling legs screwed all the way in*

41³⁄₄"

(106 cm) overall height with leveling legs screwed all the way in*

30⁹⁄₁₆"

(77.6 cm)

23" (58.4 cm)

countertop

notch to rear of countertop

35⁵⁄₈" (90.5 cm) height to underside of cooktop edge with leveling legs screwed all

the way in*

Model/serial number plate (located on the right-hand side oven door trim)

should be located in the same room but external to

the range. It should be in a location that allows ease

of opening and closing.

ELECTRICAL REQUIREMENTS

27¼" (69.2 cm) max. from handle to

standoff at back of range**

Model/serial number

 

plate (located on the

27¼" (69.2 cm) max.

right-hand side

(27¹¹⁄₁₆" [70.3 cm]

oven door trim)

on model KDSS907XSP)

 

from handle to standoff

 

at back of range**

30"

(76.2 cm)

When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz, AC only electrical supply is available, a 50- amp maximum circuit protection is required. When a 4-wire or 3-wire single phase 120/208 volt 60 Hz, AC only electrical supply is available, a 40-amp maximum circuit protection is required, fused on both sides of the line. A separate circuit is recommended. A time-delay fuse or circuit breaker is recommended.

†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.

*Range can be raised approximately

*Range can be raised approximately

1" (2.5 cm) by adjusting the leveling legs.

1" (2.5 cm) by adjusting the leveling legs.

**When installed in a 24" (61 cm) base cabinet

**When installed in a 24" (61.0 cm) base cabinet

with 25" (63.5 cm) countertop; front of oven

with 25" (63.5 cm) countertop; front of oven

door protrudes 1" (2.5 cm) beyond 24"

door protrudes 1³⁄₄" (4.4 cm) (2³⁄₁₆" [5.5 cm] on

(61 cm) base cabinet.

models KDRS807XSP and KDSS907XSP)

 

beyond 24" (61.0 cm) base cabinet.

SLIDE-IN COUNTERTOP PREPARATION

30"

(76.2 cm)

³⁄₈"

(1.0 cm)

30¾"

(78.1 cm)

The cooktop sides of the slide-in range fit over the cutout edge of your countertop.

If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.

Formed front-edged countertops must have molded edge shaved flat ³⁄₈" (1.0 cm) from each front corner of opening.

Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each front corner and/or rounded edge flattened.

If countertop opening width is greater than

30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.

Countertop must be level. Place level on countertop, first side to side; then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions.

INSTALLATION CLEARANCES

 

Freestanding Ranges

 

 

 

Slide-In Ranges

 

 

13" (33 cm) upper

For minimum

 

 

13" (33 cm) max.

For minimum

 

clearance to top

 

 

clearance to top

 

cabinet depth

of the cooktop,

 

 

upper cabinet depth

of the cooktop,

 

30" (76.2 cm) min.

 

see NOTE.

 

 

30" (76.2 cm) min.

 

see NOTE.

 

 

 

 

 

 

 

 

opening width

 

 

 

 

opening width

 

 

18" (45.7 cm)

 

 

 

18" (45.7 cm)

 

 

22¹⁵⁄₁₆" (58.3 cm)

 

 

 

 

³⁄₄" (1.9 cm)

opening depth

upper cabinet

30" (76.2 cm)

 

 

upper cabinet

 

 

 

to countertop

min. opening

 

 

to countertop

 

radius both corners

 

 

width

 

 

 

 

30" (76.2 cm)

 

 

 

 

 

 

 

min. opening

 

 

 

 

 

 

 

width

 

 

 

This shaded area

Cabinet door

 

 

 

This shaded area

Cabinet door

 

 

5" (12.7 cm) min.

 

6"

recommended

or hinge

 

8"

recommended

or hinge

 

5" (12.7 cm) min.

clearance from

 

(15.2 cm)

for installation

should not

(20.3 cm)

for installation

should not

 

clearance from

extend into

both sides of the

 

 

of outlet or

extend into

both sides of the

 

of outlet or

range to the side

 

6"

junction box.

the cutout.

8"

junction box.

the cutout.

 

 

range to the side

 

 

wall or other

(15.2 cm)

 

 

wall or other

(20.3 cm)

 

 

combustible

 

7" (17.8 cm)

 

 

combustible

7" (17.8 cm)

4¹⁄₂"

 

material.

 

4¹⁄₂"

 

material.

 

 

 

 

(11.4 cm)

 

 

 

(11.4 cm)

 

This shaded area

 

 

 

 

This shaded area

 

 

 

 

 

 

 

 

 

 

recommended for

 

 

Available

 

recommended for

 

 

 

installation of

 

1¹⁄₂"

 

installation of

1¹⁄₂"

Available

 

rigid gas pipe.

 

(3.8 cm)

area for

 

rigid gas pipe.

(3.8 cm)

area for

 

 

 

 

gas and

 

 

 

4¹⁄₂"

 

electric

 

 

 

gas and

 

 

 

4¹⁄₂"

 

electric

 

(11.4 cm)

installation.

 

(11.4 cm)

installation.

 

 

 

 

 

 

NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄"

(0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10246120C

Instructions packed with product. Specifications subject to change without notice.

1/28/11

Image 1
Contents Installation Clearances GAS Supply Requirements Product DimensionsProduct Model Numbers Electrical Requirements