UC100 Installation Manual
3.The dispenser drain lines must slope a minimum of 1/4” per foot to the floor drain, see FIGURE 2. Drain lines must be installed to comply with federal, state and local codes. It is required to fully insulate all drain lines and fittings to prevent condensation from forming!!!
Dispenser | Drain Line | |||
Drain Point |
|
| Horizontal | |
|
|
|
| Reference Line |
|
|
| 1/4” | |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1’
Floor Drain
FIGURE 2
If the unit is installed in a: 36” tall counter top, the floor drain must be within 23’ of the dispenser. 34” tall counter top, the floor drain must be within 15’ of the dispenser. 30” tall counter top, the floor drain must be within 1’ of the dispenser.
4.Clean the hopper interior (see CLEANING INSTRUCTIONS in Operator’s Manual).
5.Connect the power cord to a 120 volt, 60 cycle,
Set Up Supplied Air Compressor
1.Set up and install the air compressor, follow the manufacturer’s installation instructions.
2.Route the 1/4” beverage tube from the air compressor to the air valve solenoid inlet tube connector on the dispenser.
NOTE: The filter/regulator is preset to 50 psi and should not require adjustment.
FILTER/REGULATOR ASSEMBLY
PRESET TO 50 PSI, NO ADJUSTMENT NEEDED
AIR VALVE SOLENOID
CLEAR TUBE
CUSTOMER CONNECTION
INCOMING SUPPLY SHOULD BE
SET TO 100 PSI
AIR CYLINDER
(LOCATED IN
TOWER CLADDING)
1/4" TUBE WHIP
(SUPPLIED WITH UNIT) CLEAR RED TUBE
AIR SCHEMATIC
FIGURE 3