Foster LC125 manual Contents, Introduction, Technical Information, Temperature Controller

Page 2

DISPOSAL REQUIREMENTS

If not disposed of properly all refrigerators have components that can be harmful to the environment. All old refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance with UK laws and regulations.

Contents

Page

Introduction

1

Technical Information

1

Temperature Controller

1

Controller Parameters

2

Alarms and Warnings

2

Electrical Connections

2

Wiring Diagram

3

Introduction

Top loading meatwell for the storage of frozen products

One piece foam shell with skin evaporator and bottom

mount condensing system. R 134A refrigerant

Fitted with corner bumpers to each side.

Front smash bar as an option, fitted as standard for Burger King.

Fitted with 4 x 60mm castors.

Technical Information

Temperature Set Point

-21°C

Refrigerant

R134A

Refrigerant Charge

180 gms

Capillary

4.5mts x 042

Power supply

230/50/1

Temperature Controller

When the controller is switched on a single line appears on the display for 3 seconds to indicate the autotest period.

After this period the air temperature measured by the T1 probe is displayed.

It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained.

LDU 15 Controller

 

aux

 

lae

set

aux

Check temperature set point.

Check set point by pressing the

 

set

To increase set point press

 

 

 

 

 

set

 

+

To decrease set point press

 

 

 

+

 

set

 

 

Factory Temperature Set Point -21°C.

button

Exit from set up occurs after 10 seconds if no button is pressed.

Controller Set Up.

The parameters are accessed by pressing the following keys in succession

+

and keeping them pressed for 3 seconds.

 

Access to the parameters has been achieved with the first parameter SCL being displayed.

set

+

To pass from one parameter to the next press either the

or

To display the value press.

 

 

 

 

 

 

set

 

 

 

 

To change the value press

 

 

+

to increase, or

 

 

 

set

 

 

set

key.

+to decrease.

1

Image 2
Contents Meatwell Freezer Controller Set Up ContentsTemperature Controller IntroductionController Parameters Wiring Diagram

LC125 specifications

The Foster LC125 is a robust and versatile load cell designed for industrial weighing applications, particularly where precision and reliability are paramount. This mid-range load cell has gained popularity due to its unique combination of features, advanced technologies, and overall performance characteristics.

At the core of the Foster LC125 is its high accuracy and precision. It typically achieves a maximum capacity ranging from 1,000 kg to 10,000 kg, making it suitable for a wide range of applications in various industries, including manufacturing, logistics, and agriculture. The load cell's accuracy is maintained even under extreme conditions, thanks to advanced strain gauge technology that ensures minimal drift over time.

The construction of the LC125 is another highlight. It is built from high-grade stainless steel, which provides exceptional durability and resistance to corrosion and environmental factors. This makes it an ideal choice for applications in harsh settings, such as food processing or chemical handling, where exposure to moisture and chemicals is common. Additionally, the LC125's IP67 rating signifies its ability to withstand dust and water ingress, ensuring longevity and reliability.

Another key feature of the Foster LC125 is its variety of mounting configurations. The load cell can be installed in load cells, tanks, and other structures with ease, thanks to its adaptable design. It also integrates well with various systems, enabling seamless connection to digital displays and data acquisition systems.

In terms of technologies, the LC125 employs innovative load measurement techniques that enhance its performance. Its high-frequency response ensures accurate readings, even in dynamic loading situations. This capability is particularly crucial in industries where load conditions can change rapidly, such as in conveyor systems or during the loading and unloading of materials.

The Foster LC125 also includes advanced temperature compensation features, which minimize the impact of temperature fluctuations on measurements. This ensures that the load cell maintains its accuracy across different environmental conditions, making it a reliable choice for both indoor and outdoor applications.

In summary, the Foster LC125 load cell is a remarkable piece of engineering, combining high accuracy, durable construction, and versatile functionality. Its advanced technologies and robust design make it a preferred choice for industries requiring reliable load measurement solutions. Whether for weighing, force measurement, or control applications, the LC125 stands out as a dependable tool that meets the demands of modern industrial environments.