Freestanding Gas Range

PRODUCT MODEL NUMBERS

TGP305T

Gas supply: Use 3/4" (1.9 cm) rigid pipe gas supply line to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by CSA, 4-5 feet (122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., be used for connecting the range to the rigid gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. An individual manual shutoff valve must be located in the same room, but external to the range.

Electrical: 120-volt, 60-Hz, AC only, electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

OVERALL DIMENSIONS

26-3/4"

36"

(67.9 cm)

(91.4 cm)

depth with

cooktop

handle

height

42" (106.7 cm) overall height

24-1/4"

29-7/8" (75.9 cm)

(61.6 cm)

width

CABINET OPENING DIMENSIONS

Cabinet opening dimensions shown are for 25"

(64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height.

13" (33.0 cm) max. upper cabinet depth

NOTE: 24" (61 cm) minimum when bottom of

18" (45.7 cm) min. clearance upper side cabinet to

30" (76.2 cm) min. cabinet opening width

30-¹" (76.5 cm) opening width

2" (5.1 cm) min. countertop space to side wall or other combustible material

For minimum clearance to top of cooktop, see NOTE.

wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.

If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

countertop

This shaded area recommended for electrical outlet.

3"

(7.6 cm)

This shaded area recommended for installation

of gas pipe.

10" (25.4 cm)

24"

(61.0 cm)

8"

5" (20.3 cm)

(12.7 cm)

5"

(12.7 cm) 2"

(5.1 cm)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10130752

Instructions packed with product. Specifications subject to change without notice.