Gaggenau VG 232 CA manual Operating principle Off Low High

Page 9

2.3 Operating principle

Off

Low

High

Fig. 4

The appliance features one-hand operation. That is to say, the ignition is activated when the control knob is pressed briefly.

After igniting, keep the control knob pressed for around 5-8 seconds more because the heat sensor that opens the gas channel has to warm up first.

The gas hob has 1 normal burner (front burner) and 1 high-intensity burner (rear burner).

All burners have a thermal protection device that prevents unburned gas from escaping in the open position.

The total rated thermal load amounts to:

16000 BTU (4.7 kW) referred to Hs* (gross calorific value)

14300 BTU (4.2 kW) referred to Hi (calorific value) The specified rated load is defined by installation of the fixed nozzles.

The gas hob is converted to a different gas type by nozzle replacement (full and low-burning nozzles) (see nozzle table on p. 12).

The symbols on the control panel mean:

0Off

High setting

Low setting

The flame is infinitely variable between high and low-setting.

Maintenance Instructions

Keep appliance area clean and free from combustible materials, gasoline and other inflammable vapors and liquids.

Do not obstruct the flow of combustion and ventilation air.

Visually check burner flames with this pictorial representation (see figure 4).

8

Image 9
Contents Gas cooker Operating and assembly instructionsVG 232 CA For Your SafetyFor Your Safety CAN/CSA Z240 MH CAN/CSA Z240 RV Preface For your safety Important notesOperating for the first time About use Special accessories Structure and operating principleStructure Operating principle Off Low High Operation Cleaning and care General Remedying slight malfunctions yourself Maintenance∑ Consumption 45 m3/h 340 g/h Technical data / Settings tableGaggenau Hausgeräte Gmbh