Franklin Industries, L.L.C FCR36OD Operating the Internal Light, Defrosting Cycle, Alarm Mode

Page 9

Operating the Internal Light

This appliance has an internal light to make it easier for you to see the foods you have stored. When the door is open, the light will be on and when it is closed, the light will be off.

Defrosting Cycle

The defrosting cycle is 12 hours. After running for 12 hours, the compressor stops for 40 minutes, but the inner fan motor runs for 40 minutes to remove frost at the same time. The defrosting water will flow into the tray on the compressor. Although the water will be evaporated by the heat of the compressor, you should check the tray regularly to avoid the water overflowing to the floor.

ALARM Mode

The unit will make a beeping sound when the thermostatic sensor has malfunctioned. When this happens, the unit works and stops regularly. Contact your authorized service facility for sensor replacement.

Shelving and Wire Basket

The shelves in your unit can be moved to different levels to suit your food storage needs. There is a can dispenser in the door, and the door shelves provide storage for small and large items and a bottle storage area for tall bottles.

The removable wire basket is convenient for storing and transporting a wide variety of foods and beverages.

Replacement of the lamp

Warning: To avoid an electric shock, unplug the unit when replacing the lamp bulb.

Bulb

Lamp socket

Lamp cover

Screw

The lamp base is E26; rated power of the lamp is 15W. Use a bulb of the same rating when replacing. When replacing the light bulb, remove the screws on the lamp shield to release the shield. Then replace with the same size and type bulb and fix the shield back into place.

8

Image 9
Contents Model/Modelo FCR36OD Outdoor Refrigerator Refrigerador de intemperiePage Table of Contents Important Safeguards Locations of Parts Technical SpecificationsEnergy-Saving Tips InstallationUse of Extension Cords Electrical ConnectionTemperature Setting Operating Your RefrigeratorTurning on the Unit Shelving and Wire Basket Alarm ModeReplacement of the lamp Operating the Internal LightCare and Cleaning Cleaning the OutsideCleaning the Inside Troubleshooting Franklin Industries, L.L.C Limited WarrantyŒndice `GUARDE Estas Instrucciones Especificaciones t cnicas Ubicaci n de piezasPage Instalaci n Consejos para ahorrar energ aUso de cables de extensi n Conexi n el ctricaOperaci n de su refrigerador Encendido de la unidadAjuste de temperatura Operaci n de la luz interna Modo de AlarmaDescongelaci n durante la operaci n Repisas y cesta de alambrePage Cuidado y limpieza Limpieza del exteriorLimpieza del interior Ruido o vibraci n El refrigerador no se enciendeSe enciende y se apaga frecuentemente Refrigerador demasiado calienteGarant a limitada FCR36OD OM-ES-1

FCR36OD specifications

Franklin Industries, L.L.C has made significant strides in the manufacturing and distribution of advanced industrial products, particularly with their innovative FCR36OD model. This robust component is designed specifically for the oil and gas sector, showcasing a blend of durability, efficiency, and cutting-edge technology.

The FCR36OD, standing for Franklin Compression Ring, features a 36-inch outer diameter that accommodates a wide range of applications. One of its main characteristics is the high-strength material used in its construction, ensuring that it can withstand extreme pressures and harsh environmental conditions typically encountered in oil and gas extraction processes. This resilience reduces the risk of failure, contributing to overall operational safety and reliability.

In terms of technology, the FCR36OD incorporates advanced engineering techniques, including precision machining and CAD-based design. These methodologies allow for exact specifications, improving the fit and function of the compression ring within its intended system. Additionally, the product is subjected to rigorous quality control measures, including stress testing and performance evaluations, ensuring it meets industry standards.

One of the standout features of the FCR36OD is its enhanced sealing capabilities. Designed with a specialized lip configuration, it effectively prevents leaks, a crucial aspect in high-stakes environments where contaminants can compromise operations. This feature not only improves safety but also optimizes the longevity of equipment by preventing fluid intrusion.

Moreover, the FCR36OD is compatible with various lubricants and chemicals, making it a versatile option for different processing needs. Its ability to maintain performance across different temperatures and pressures sets it apart from other products on the market.

The installation of the FCR36OD is also user-friendly, with a lightweight design that simplifies handling. This aspect is particularly important for field operations, where efficiency and speed are paramount. Overall, Franklin Industries, L.L.C. has tailored the FCR36OD to meet the demands of modern industrial applications, ensuring it delivers exceptional performance, durability, and reliability for customers in the oil and gas sector. As the industry evolves, products like the FCR36OD will undoubtedly play a crucial role in enhancing operational efficiency and safety.