Aga Ranges Aga 30AIM 115V manual Cleaning Your Ice machine

Page 8

Caring for Your Ice Machine

Cleaning Your Ice machine

Some impurities will remain and build-up in the ice machine and stick to the ice machine's parts over time. This build-up must be removed for proper ice production, ice quality, and ice machine life. Your ice machine is equipped with a cleaning mode that will help in cleaning out these impurities.

The impurities will regularly (at the very least, annually) need to be cleaned of this build-up, depending on use and water hardness. You can use an acid such as one specified for ice machine cleaning or you can use citric acid to remove the build-up. To clean the ice machine:

1.Switch the selector switch to the "OFF" position.

2.Remove the drain plug at the bottom of the reser- voir to drain any remaining water and then reinstall.

3.Add the recommend cleaner solution to the reser- voir of the ice machine. Access to the reservoir can be obtained by removing the front panel screws and the front panel. Determine to proper amount of cleaner from the ice machine cleaner manufac- turer's mixture ratio based on 3 quarts of water (refer to manufacturer's directions).

4.Replace the front cover panel and close the door.

5.Switch the selector switch on the grille of the ice machine the clean position. Three quarts of water will automatically be added to the cleaning solution.

6.The total cleaning time will end in 49 minutes. The cleaning cycle will automatically rinse the evapora- tor plate and also drain the cleaning solution and rinse water.

Read manufacturer's warnings on ice machine cleaner

products. Personal injury can result.

7.After the cleaning cycle has ended, remove the front panel again and check that the build up has been removed. The evaporator plate should be clean, shiny, and smooth to the touch. If build up is still visible, repeat the cleaning cycle above. If build up is removed, continue below.

8.Remove the distributor tube, hose clamp, hose and its rubber ends.

9.Thoroughly clean the inside of the distributor tube and the spray holes. You can use the same cleaning solution as before and an old toothbrush to reach the inside of the distributor tube.

10.Reinstall the rubber ends, hose, and hose clamp to the distributor and then reinstall the distributor tube to the evaporator with the spray holes pointed to the bottom of the evaporator plate. Reinstall the front cover panel with the two front panel screws.

11.Clean the ice machine's interior, ice scoop, interior door panel and door gasket with mild soap and

water. Using two tablespoons of baking soda in one quart of warm water while cleaning will help remove odors. Rinse with fresh water. Do not use any abra- sive cleaning products.

Your ice machine is now clean and sanitized and may be put back into operation by switching the selector witch to the "ON" position.

All specifications and product design subject to change without notice.

7

Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.

Image 8
Contents Aga 30AIM Starting Out Installation Select LocationCabinet Clearance Electrical ConnectionGravity Drain Location Installation Drain PlumbingDrain Plumbing Water Supply Water SupplyPage Caring for Your Ice Machine OperationCare of Unit Normal Responsibilities of the OwnerReplace the front cover panel and close the door Cleaning Your Ice machineSwitch the selector switch to the OFF position Things to Remember Things to RememberObtaining Service Before Calling for ServiceHow to Obtain Service For Your RecordsTroubleshooting One Ice slab not releasing Trouble Shooting TwoCharge line, and vent line for any build or restrictions Trouble Shooting Three Troubleshooting Four Warranty Household Refrigeration Products Limited WarrantyBox 997 Richmond, Indiana 800.243.1624Page Aga Ranges/Refrigeration Products Division