1SAFETY AND WARNINGS

WARNING!

Electrical hazard

Always disconnect the oven from the mains electricity supply before carrying out any maintenance operations or repairs.

Failure to do so may result in electrical shock or death.

SINGLE DOUBLE OVEN OVEN MODELS MODELS

 

WARNING!

 

Very Heavy

409 lb

Do not attempt to lift this

186 kg

product unassisted.

 

Lifting unassisted may

 

cause serious injury.

242lb

110 kg

Before you install the oven, please make sure that

The oven will rest on a surface that can support its weight.

The countertop and oven cavity are square and level, and are the required dimensions. The height from the ￿oor suits the user.

The oven door can open fully without obstruction.

Electrical requirements

Connect oven with copper wire only.

Do not cut the conduit.

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

Important safety precautions!

Save these instructions for the local inspectors’ use.

To avoid hazard, follow these instructions carefully before installing or using this product.

Please make this information available to the person installing the product as it could reduce your installation costs.

This oven is to be installed and connected to the electricity supply only by an authorized person.

If the installation requires alterations to the domestic electrical system, call a quali￿ed electrician. The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven. The oven must be grounded.

To connect the oven to the mains, do not use adapters, reducers or branching devices as they can cause overheating and burning.

Installation must comply with your local building and electricity regulations. Failure to install the oven correctly could invalidate any warranty or liability claims.

A U.L. listed conduit connector must be provided at the junction box. Do not ground to a gas pipe.

Do not have a fuse in the grounding or neutral circuit. Fuse both sides of the line.

A time delay fuse or circuit breaker is recommended. If using a time delay fuse, then fuse both sides of the line.

Flexible armored cable from the appliance should be connected directly to the junction box.

Connect directly to the fused disconnect (or circuit breaker box) through ￿exible, armored or non-metallic sheathed, copper cable (with grounding wire).

If codes permit and a separate grounding wire is used, it is recommended that a quali￿ed electrician determine that the grounding path and wire gauge are in accordance with local codes.

Do not use an extension cord with this appliance.

When you install the oven

Do not seal the oven into the cabinetry with silicone or glue. This makes future servicing di￿cult. Fisher & Paykel will not cover the costs of removing the oven, or of damage caused by this removal.

Use the supplied screws to secure the oven to the cabinetry. Do not over-tighten the screws. Do not stand on the door, or place heavy objects on it.

Do not lift the oven by the door handle.

Take extra care not to damage the lower trim of the oven.

Image 1
Contents Electrical hazard Safety and WarningsSingle oven models Double oven models Product and Cabinetry DimensionsElectrical Connection to Junction BOX Unpack the Oven and Remove the DoorsSecure the Oven to the Cabinetry and Refit the Doors Final Checklist
Related manuals
Manual 84 pages 20.53 Kb

WOU130, WOUD230 specifications

DCS WOUD230 and WOU130 are advanced air quality monitoring devices designed to provide real-time data on environmental conditions. These systems represent the latest in monitoring technology, catering to a variety of applications, from industrial settings to urban environments.

The DCS WOUD230 is equipped with a high-precision sensor suite that measures a range of pollutants, including particulate matter (PM2.5 and PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3). Its ability to detect these pollutants allows for comprehensive air quality assessments, making it an excellent choice for regulatory compliance and environmental research.

On the other hand, the DCS WOU130 is designed with energy efficiency in mind. It utilizes low-power technologies that ensure continuous operation without excessive energy consumption. This makes it suitable for deployment in remote locations where power supply may be limited. Both devices feature ruggedized designs, making them highly durable and capable of withstanding harsh environmental conditions.

One of the standout features of both the WOUD230 and WOU130 is their connectivity options. They are equipped with Wi-Fi and cellular communication capabilities, enabling seamless data transfer to cloud-based platforms. This allows users to access real-time data from anywhere in the world through a user-friendly interface. Additionally, both models can be integrated with existing environmental monitoring systems, providing flexibility and scalability.

Another key characteristic of these devices is their advanced data analytics capabilities. They come with built-in algorithms that not only collect data but analyze it to identify trends and patterns in air quality over time. This functionality is essential for researchers and policymakers who need to make informed decisions based on reliable data.

Moreover, the WOUD230 and WOU130 include alert systems that notify users of sudden changes in air quality, facilitating timely responses to potential hazards. This feature is particularly important in urban areas where pollution levels can fluctuate rapidly due to traffic, construction, or weather conditions.

In conclusion, the DCS WOUD230 and WOU130 air quality monitors are powerful tools equipped with cutting-edge technologies that provide reliable and actionable environmental data. Their combination of precision, connectivity, and durability makes them indispensable for anyone looking to monitor air quality effectively. Whether for industrial compliance, scientific research, or public health awareness, these devices play a critical role in understanding and improving our environment.