Safe Chill™ Blast Chillers Service & Installation Manual
Safe Chill™ Control | OPERATION CONTINUED... | |
|
|
|
Probe | Box | Time | Time |
Temp | Temp | Elapsed | Remaining |
Defrost Mode: After chilling/freezing the unit will go into a defrost mode for 15 minutes or until the coil reaches a temperature of 70˚(DF1). During the freezer preservation mode the defrost heater will operate for 15 minutes (DF2) or until the coil reaches a temperature of 70˚F(DF1) every 6 hours (DF3).
Tandem Mode
Individual Mode
Operating the Control
1.Start Cycle
•Press MODE button, display will change.
•Press MODE button until desired mode (soft, hard, freeze) appears in left hand upper corner of display.
•Press START/STOP button, unit will start cycle.
2.Start cycle in individual mode (DBC-10 only):
•Press MODE button, display will change
•Press MODE button until “Indiv” appears in left hand upper corner of display.
•Press ENTER button.
•Press MODE button until desired mode (soft, hard, freeze) appears in left hand upper corner of display.
•Press START/STOP button, unit will start cycle.
3.Start cycle in timed mode
•Press MODE button, display will change
•Press MODE button until “Indiv” appears in left hand upper corner of display.
•Press TIMED button, counter will appear in right hand upper corner of display.
•Press UP/DOWN buttons to adjust timer to desired setting.
•Press START/STOP button, unit will start cycle.
4.To stop a cycle:
•Press START/STOP button for one second.
If unit is a
Soft | Hard | Blast | Dual |
Chill | Chill | Freeze | Mode |