Safe Chill™ Blast Chillers Service & Installation Manual

Safe Chill™ Control

OPERATION CONTINUED...

 

 

 

Probe

Box

Time

Time

Temp

Temp

Elapsed

Remaining

Defrost Mode: After chilling/freezing the unit will go into a defrost mode for 15 minutes or until the coil reaches a temperature of 70˚(DF1). During the freezer preservation mode the defrost heater will operate for 15 minutes (DF2) or until the coil reaches a temperature of 70˚F(DF1) every 6 hours (DF3).

Tandem Mode (DBC-10 only): In this mode, both the upper and lower compartments will start at the same time running in the same mode of operation (soft, hard, or freezer mode). Once operating the compartments cycle independently. For example, if the bottom compartment pulls down quicker than the top it will shut down without affecting the tops operation.

Individual Mode (DBC-10 only): This mode allows operation of the two compartments in different modes of operation starting them at different times. For example, the top compartment can be loaded to run in a timed soft chill cycle, and at any time the bottom could be loaded in a freezer mode and started.

Operating the Control

1.Start Cycle (DBC-10 will start both upper and lower units):

Press MODE button, display will change.

Press MODE button until desired mode (soft, hard, freeze) appears in left hand upper corner of display.

Press START/STOP button, unit will start cycle.

2.Start cycle in individual mode (DBC-10 only):

Press MODE button, display will change

Press MODE button until “Indiv” appears in left hand upper corner of display.

Press ENTER button.

Press MODE button until desired mode (soft, hard, freeze) appears in left hand upper corner of display.

Press START/STOP button, unit will start cycle.

3.Start cycle in timed mode (DBC-10 only will start both upper and lower units):

Press MODE button, display will change

Press MODE button until “Indiv” appears in left hand upper corner of display.

Press TIMED button, counter will appear in right hand upper corner of display.

Press UP/DOWN buttons to adjust timer to desired setting.

Press START/STOP button, unit will start cycle.

4.To stop a cycle:

Press START/STOP button for one second.

If unit is a DBC-5 or DBC-5U cycle will shut down. DBC-10 If only one compartment is running, cycle will shut down. If both compartments are running, display will prompt you to shut entire unit down by pressing START/STOP button. To shut down the individual compartments press the UP button for the top or the DOWN button for the bottom.

Soft

Hard

Blast

Dual

Chill

Chill

Freeze

Mode

4For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com

Image 4
Contents Safe Chill Blast Chillers Model DBC-10Receiving and Inspecting the Equipment Contents Serial Number InformationSafe Chill Blast Chiller Mechanical Data Installation Start cycle in individual mode DBC-10 only To stop a cycleSetting Clock Alarms and FaultsStart cycle with one unit running DBC-10 only PrintingList of Parameters Food ProbesWiring Diagram Safe Chill Blast Chillers Service & Installation Manual Safe Chill Blast Chillers Service & Installation Manual Original Purchaser must accept delivery of the replace General Conditions Delfield Authorized Parts Depots