5925 Heisley Road • Mentor, OH
Ovens Humidity with | ||
Microprocessor Controls | ||
| ||
Rev. 8 (1/05) | Page 3 of 13 |
INSTALLATION INSTRUCTIONS
VENTING YOUR OVEN:
1.The purpose of ventilating hoods is to direct and capture smoke,
2.Low temperature equipment (maximum temperature 250°F/121°C) does not produce heat, odors, fumes,
3.Most jurisdictions consider our
4.Installation must conform with local codes. The authority having jurisdiction of enforcement of the codes will have the responsibility for making interpretations of the rules.
UNIT SPECIFICATIONS: All units use three (3) elements (2670 watts each).
All units are rated 8200 watts. Water units have one (1) immersion element (1850 watts).
CONVECTION OVENS | ELECTRICAL SPECS | ELEC. LOAD | POWER SUPPLY REQUIREMENT | ||||||||
(AC SERVICE) | |||||||||||
CMP MODEL NOS. |
|
|
|
|
|
|
| ||||
Volts | Ph | Hz. | Amps | Volts | Amps | Ph | Wire | Volts | NEMA | ||
| |||||||||||
CO151FWUA12B2081Q1 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 3 | 208 | ||
CO151FWUA12B2401Q1 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 3 | 240 | ||
CO151FWUA12B2083Q1 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 4 | 208 | ||
CO151FWUA12B2403Q1 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 4 | 240 | ||
RETHERM OVENS |
|
|
|
|
|
|
|
|
|
| |
RO151FWUA18B2081Q1 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 3 | 208 | ||
RO151FWUA18B2401Q1 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 3 | 240 | ||
RO151FWUA18B2083Q1 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 4 | 208 | ||
RO151FWUA18B2403Q1 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 4 | 240 | ||
RO151FW1332B2081Q1 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 3 | 208 | ||
RO151FW1332B2401Q1 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 3 | 240 | ||
RO151FW1332B2083Q1 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 4 | 208 | ||
RO151FW1332B2403Q1 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 4 | 240 | ||
RATED | AT 4950 WATTS (THREE [3] HEATERS AT 1470 WATTS EACH) |
| |||||||||
CO151HWUA6B2081Q1 | 208 | 1 | 60 | 24 | 208 | 30 | 1 | 3 | 208 | ||
CO151HWUA6B2401Q1 | 240 | 1 | 60 | 21 | 240 | 30 | 1 | 3 | 240 | ||
CO151HWUA6B2083Q1 | 208 | 3 | 60 | 15 | 208 | 20 | 3 | 4 | 208 | ||
CO151HWUA6B2403Q1 | 240 | 3 | 60 | 13 | 240 | 20 | 3 | 4 | 240 | ||
CO151XWUA5B2081Q1 | 208 | 1 | 60 | 24 | 208 | 30 | 1 | 3 | 208 | ||
CO151XWUA5B2401Q1 | 240 | 1 | 60 | 21 | 240 | 30 | 1 | 3 | 240 | ||
CO151XWUA5B2083Q1 | 208 | 3 | 60 | 15 | 208 | 20 | 3 | 4 | 208 | ||
CO151XWUA5B2403Q1 | 240 | 3 | 60 | 13 | 240 | 20 | 3 | 4 | 240 |
All models are designed for AC Service. Model numbers may have the letters: L, M, 2M, or S.
HOW TO INSTALL CABINETS:
1.Remove all packing material from inside and outside of cabinet.
2.Position cabinet on level floor; install the cabinet interior (pan slides) if not already installed.
3.Plug power cord into proper wall receptacle.
4.Fill water pan with three (3) gallons of HOT water (see CAUTION).
LOW WATER LIGHT:
When water needs to be added to the pan, the Low Water Light will stay on until the pan is refilled.
Use of treated water is recommended for proper operation and
to maintain warranty. It will reduce scaling.