Creda CB01E manual Oven Unit Housing Cabinets, Electrical Installation, Mains Supply

Page 31

Installation Instructions

2.Oven Unit Housing Cabinets

(a)The oven unit housing cabinet dimensions must comply with Fig. 3 and Fig. 4.

(b)An air gap of 50mm minimum must be provided at the rear of any top or bottom cupboards or shelves for ventilation.

(c)Do not obstruct the ventilation slots provided on the oven trim. This is found adjacent to the bottom of the oven door.

(d)The air gap at the rear allows the warmed air to pass out of the cabinet. If cabinets extend up to the ceiling, the warm air must be exhausted through to the front. Fig. 1.

(e)If an oven unit is installed adjacent to a tall cabinet, steam escaping from the oven when the door is opened could condense on, and perhaps stain the adjacent surface. To prevent permanent staining, the adjacent surface should be made of a material that is heat resisting and easy to clean. Adjacent tall cabinets should not be deeper than the oven housing cabinet.

Important

It is essential that the lower cupboard is constructed in the manner illustrated i.e. having side, back and roof panels so joined as to provide no apertures which could permit access to the oven unit when installed.

3. Electrical Installation

Mains Supply

A 20 amp Double Pole control switch with a minimum contact clearance of 3mm must be fitted on or recessed in the wall adjacent to the oven housing cabinetry and should be accessible after installation. If the oven is to be wired into a connector unit this may be positioned behind the oven providing:–

i.The top of the connector unit is not more than 30cm above the base of the oven recess – see Fig. 4.

ii.The depth of the connector unit does not reduce the depth of the oven recess to less than 55cm.

We recommend that 4mm2 twin and earth PVC insulated cable is used to connect the cooker to the control unit. This power supply cable must conform to BS 6004.

Alternatively the mains supply can be taken from a household 13 amp switched fused spur having a minimum contact clearance of 3mm, which must be fitted adjacent to the oven housing cabinetry and accessible after installation. The oven must be fitted with a 3 core cable having a minimum cross sectional area of 1.5mm2 and must conform to BS6500.

The oven must not be connected using a 3 pin 13 amp plug.

31

Image 31
Contents CB01E Creda Answer Centre 08701 54 64 Creda Answer Centre 08701 54 64Contents Disposal of your product IntroductionSafety Advice Safety InformationAlways Safety Information Never Features Control markings ControlsOven Timer Operation Clockface Know Your TimerSymbols Timer Function ButtonsSetting the Minute Minder Setting the Time of DAYAuto Cooking Programmes Electronic Clock and Automatic Oven Timer Operation Other Notes on Timer Operation Speedgrill Grill Pan Food Grid and Anti-Splash Tray Grill Pan and HandleStep Door Position for Grilling Grilling ProcedureFood Grill ChartOven utensils Using the Oven for Fan CookingTemperature and time Oven shelf positioning for fan ovenFan oven operation Using the Oven for other Functions Conventional Fan Temperature Conversion ChartOven If Using Aluminium Foil Oven Temperature Chart MeatBaking Fan Oven Cooking Oven Temperature Chart BakingGrill Cooking Results Not SatisfactoryBaking General Cleaning Care and CleaningCredaclean Oven Liners How Credaclean worksSpeedgrill Cleaning the OvenBase of Main Oven Meat b Grill/Meat Pan & Oven Shelves HOW to Clean the Lamp Lens Replacement of the Oven Lamp Control Panel / Trims / Inner Door Panel & Glass Remove the door inner glass as follows Cleaning the DoorsRefit the door inner glass as follows General Installation InstructionsElectrical Installation Oven Unit Housing CabinetsMains Supply All cases adhere to routing details see fig Final InstallationConduit Box to Mains Terminal Block List of Loose Items560mm 550mm Something Wrong? Problem CheckKey Contacts