Creda 41202 installation instructions Mm Min

Page 21

Installation Instructions

The cooker can be close fitted below hotplate level. This requires a minimum distance of 503mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm.

The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc.

The wall behind the cooker 150mm below the hotplate and 450mm above, and the width of the cooker, must be a non- combustible material such as ceramic wall tiles.

If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when removing oven shelves.

65 mm Min

503 mm Min

Cooker Hoods If a cooker hood is to be installed, refer to the cooker hood manu-

facturers’ instructions regarding fixing height.

21

Image 21
Contents Capri Creda Answer Centre 0541 54 64 Contents Introduction Always For Your SafetyFor Your Safety Never USE Instructions Hotplate Grill Grill Pan and HandleTo Use the Grill Relighting the Burner Grill Oven RelightingBurner Roasting of Large Cold Start CookingPoultry StorageMeat and Poultry Oven Cooking ChartYeast Mixtures Using the ‘E’ Setting for Slow Cooking ‘E’ SettingCare and Cleaning Cooker Finish Cleaning Method Slight odour or small Too slowIgnition does not work Installation Instructions Gas Safety Installation & Use Regulations LocationProvision for Ventilation General Technical Data DimensionMm Min Unpacking the Cooker Connecting To The Gas SupplyInstallation Instructions Your In-Guarantee Service Telephone Number Service