Delta Electronics KHB1248GHS dimensions New, Dimensions Drawing, Mounting Panel Cutout, Function

Page 1

KHB 120 x 54 MM SERIES

New

DIMENSIONS DRAWING

 

120.0

0.5

(

4.724

0.020)

 

98.5

0.5

(

3.878

0.020)

54.00.8

(2.126 0.031)

40.50.5

(1.594 0.020)

47.00.5

(1.850 0.020)

M4(5X)

(ONE FOR GROUNDING)

M4(4X)

47.0 0.5

1.850 0.020)

58.0 0.5

2.283 0.020)

65.0 0.5

( 2.559 0.020)

 

(

 

(

 

 

10.0

(0.394)

80.0 10.0

(3.150 0.394)

345.0 10.0

(13.583 0.394)

mm

UNIT :

(INCH)

* Bearing Type

Ball Bearings

Material

P & Q CURVE (AT RATED VOLTAGE)

MOUNTING PANEL CUTOUT

*

Impeller : Plastic (UL 94V-0)

Pillow : Die-Cast Aluminum

* Lead Wires :

UL 1007 AWG #24 Or Equivalent

Red Wire Positive (+)

Black Wire Negative (-)

* Weight : 330g (11.64 oz)

 

2.0

 

 

 

KHB1248XXS

 

 

 

 

50.0

 

 

 

 

 

 

 

 

 

1.6

40.0

 

 

 

 

 

EH

 

 

Pressure

0.8

20.0

 

 

 

 

 

SH

 

2.0

 

1.2

30.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VH

 

Air

0.4

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0

0.0

0

1.0

2.0

3.0

4.0

5.0

6.0

(M3/MIN)

 

O)

O)

 

 

 

 

 

 

 

 

 

 

2

2

0

40

80

120

160

200

(CFM)

 

H

H

 

(IN

(mm

 

 

Air Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*INLET RING:

 

 

 

REF.)

 

146.0 REF.

18.0

(0.709)

(

5.748 REF.)

 

 

 

 

 

96.0 REF.

 

 

 

(

3.780 REF.)

 

 

(0.079

.0

 

 

 

R16

 

 

 

 

.630)

 

 

 

 

(R0

 

 

 

mm

UNIT :

(INCH)

 

 

Rated

Operating

Input

Input

 

Maximum

Maximum

 

MODEL

Voltage

Speed

Noise

Voltage

Current

Power

Air Flow

Air Pressure

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

PART NO.

FUNCTION

VDC

VDC

Amp

Watt

R.P.M.

 

CFM

mmH2 O

IN H 2 O

dB-A

KHB1248VHS

-R00 / -F00

48

32.0

to 80.0

0.27

12.96

3100

3.520

124.30

20.60

0.810

53.5

KHB1248SHS

-R00 / -F00

48

32.0

to 80.0

0.35

16.80

3500

4.000

141.30

27.00

1.070

57.5

KHB1248EHS

-R00 / -F00

48

32.0

to 80.0

0.47

22.56

4100

4.680

165.30

38.20

1.500

61.5

*Function type is optional.

*The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.

*Noise is measured in anechoic chamber in free air, one meter from intake side.

*All readings are typical values at rated voltage.

*Specifications are subject to change without notice.

132

http://www.deltaww.com

Image 1
Contents New Dimensions DrawingMounting Panel Cutout Function