KHB  120 x 54 MM SERIES
 120 x 54 MM SERIES
New
 DIMENSIONS DRAWING
 DIMENSIONS DRAWING
| 
 | 120.0 | 0.5 | 
| ( | 4.724 | 0.020) | 
| 
 | 98.5 | 0.5 | 
| ( | 3.878 | 0.020) | 
54.0 0.8
0.8
(2.126  0.031)
 0.031)
40.5 0.5
0.5
(1.594 0.020)
 0.020)
47.0 0.5
0.5
(1.850  0.020)
 0.020)
M4(5X)
(ONE FOR GROUNDING)
M4(4X)
| 47.0 0.5 | 1.850 0.020) | 58.0 0.5 | 2.283 0.020) | 65.0 0.5 | ( 2.559 0.020) | 
| 
 | ( | 
 | ( | 
 | 
 | 
| 10.0 | (0.394) | 80.0 10.0 | (3.150 0.394) | 345.0 10.0 | (13.583 0.394) | 
mm
UNIT :
(INCH)
| * Bearing Type | 
| Ball Bearings | 
| Material | 
| P & Q CURVE (AT RATED VOLTAGE) | MOUNTING PANEL CUTOUT | 
| * | 
| Impeller : Plastic (UL  | 
| Pillow :  | 
| * Lead Wires : | 
| UL 1007 AWG #24 Or Equivalent | 
| Red Wire Positive (+) | 
| Black Wire Negative  | 
| * Weight : 330g (11.64 oz) | 
| 
 | 2.0 | 
 | 
 | 
 | KHB1248XXS | 
 | 
 | 
 | ||
| 
 | 50.0 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 1.6 | 40.0 | 
 | 
 | 
 | 
 | 
 | EH | 
 | 
 | 
| Pressure | 0.8 | 20.0 | 
 | 
 | 
 | 
 | 
 | SH | 
 | 2.0 | 
| 
 | 1.2 | 30.0 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | VH | 
 | |
| Air | 0.4 | 10.0 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 0.0 | 0.0 | 0 | 1.0 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 | (M3/MIN) | 
| 
 | O) | O) | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 2 | 2 | 0 | 40 | 80 | 120 | 160 | 200 | (CFM) | |
| 
 | H | H | ||||||||
| 
 | (IN | (mm | 
 | 
 | Air Flow | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | *INLET RING: | 
 | 
 | 
 | |
| REF.) | 
 | 146.0 REF. | 18.0 | (0.709) | |
| ( | 5.748 REF.) | ||||
| 
 | 
 | 
 | |||
| 
 | 
 | 96.0 REF. | 
 | 
 | |
| 
 | ( | 3.780 REF.) | 
 | 
 | |
| (0.079 | .0 | 
 | 
 | 
 | |
| R16 | 
 | 
 | 
 | ||
| 
 | .630) | 
 | 
 | 
 | |
| 
 | (R0 | 
 | 
 | 
 | 
mm
UNIT :
(INCH)
| 
 | 
 | Rated | Operating | Input | Input | 
 | Maximum | Maximum | 
 | ||||
| MODEL | Voltage | Speed | Noise | ||||||||||
| Voltage | Current | Power | Air Flow | Air Pressure | |||||||||
| 
 | 
 | Range | 
 | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| PART NO. | FUNCTION | VDC | VDC | Amp | Watt | R.P.M. | 
 | CFM | mmH2 O | IN H 2 O | |||
| KHB1248VHS | 48 | 32.0 | to 80.0 | 0.27 | 12.96 | 3100 | 3.520 | 124.30 | 20.60 | 0.810 | 53.5 | ||
| KHB1248SHS | 48 | 32.0 | to 80.0 | 0.35 | 16.80 | 3500 | 4.000 | 141.30 | 27.00 | 1.070 | 57.5 | ||
| KHB1248EHS | 
 | 48 | 32.0 | to 80.0 | 0.47 | 22.56 | 4100 | 4.680 | 165.30 | 38.20 | 1.500 | 61.5 | |
*Function type is optional.
*The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
*Noise is measured in anechoic chamber in free air, one meter from intake side.
*All readings are typical values at rated voltage.
*Specifications are subject to change without notice.
132