Delta Electronics AFB0305HA, AFB0312MA dimensions AFB 30 x 30 x 10 MM Series, Dimensions Drawing

Page 1

AFB 30 x 30 x 10 MM SERIES

DIMENSIONS DRAWING

* Bearing Type

30.0±0.5

(1.181±0.020)

24.0±0.3

 

 

(0.945±0.012)

30.0±0.5

(1.181±0.020)

24.0±0.3

(0.945±0.012)

LABEL

4-Ø3.2±0.3

(4-Ø0.126±0.012)

10.0±0.5

(0.394±0.020)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.394)

 

 

 

 

 

 

 

 

 

 

 

mm

 

150.0±10.0

 

 

 

 

 

 

 

 

 

 

UNIT :

 

 

 

 

 

 

 

 

 

 

 

(INCH)

 

(5.901±0.394)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ball Bearings

* Material

P & Q CURVE (AT RATED VOLTAGE) MOUNTING PANEL CUTOUT

Impeller & Frame : Plastic(UL 94V-0)

* Lead Wires :

UL 1061 AWG #26 OR Equivalent

Red Wire Positive(+)

Black Wire Negative(-)

* Weight : 10.5g (0.37 OZ)

* Rib Type Only

 

0.12

3.0

 

AFB0305/12XA-A

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10

2.5

 

 

 

 

H

 

 

 

 

0.08

 

 

 

 

 

 

 

 

 

2.0

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

0.06

1.5

 

 

 

 

L

 

24.0

(0.945)

0.04

1.0

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

0.02

0.5

 

 

 

 

 

 

 

 

 

 

0

0

.025

.050

.075

.100

.125 (M3/MIN)

 

 

O)

O)

0

1.0

2.0

3.0

 

4.0

(CFM)

 

 

2

2

 

 

 

H

H

 

 

Air Flow

 

 

 

 

 

(IN

(mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTLET SIDE

24.0

(0.945)

.0 Ø29.142) (Ø1

4-Ø3.2 (4-Ø0.126)

24.0

(0.945)

INLET SIDE

24.0

(0.945)

.0 Ø29.142) (Ø1

4-Ø3.2 (4-Ø0.126)

mm

UNIT : (INCH)

 

 

 

Rated

Operating

Input

Input

 

Maximum

Maximum

 

MODEL

 

Voltage

Speed

Noise

 

Voltage

Current

Power

Air Flow

Air Pressure

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PART NO.

REV.

FUNCTION

VDC

VDC

Amp

Watt

R.P.M.

m3 /min

CFM

mmH2O

IN H2O

dB-A

AFB0305LA

-A

-R00 / -F00

5

4.0 to 5.5

0.07

0.35

6000

0.067

2.37

1.00

0.040

17.5

AFB0312LA

-A

-R00 / -F00

12

9.5 to 13.8

0.05

0.60

 

 

 

 

 

 

AFB0305MA

-A

-R00 / -F00

5

4.0 to 5.5

0.09

0.45

7500

0.085

3.00

1.50

0.060

20.0

AFB0312MA

-A

-R00 / -F00

12

9.5 to 13.8

0.07

0.84

 

 

 

 

 

 

AFB0305HA

-A

-R00 / -F00

5

4.0 to 5.5

0.16

0.80

9000

0.100

3.53

2.50

0.100

25.0

AFB0312HA

-A

-R00 / -F00

12

9.5 to 13.8

0.09

1.08

 

 

 

 

 

 

* Function type is optional.

*The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.

*Noise is measured in anechoic chamber in free air, one meter from intake side.

* All readings are typical values at rated voltage.

* Specifications are subject to change without notice.

http://www.deltaww.com

Image 1
Contents AFB 30 x 30 x 10 MM Series Dimensions DrawingCurve AT Rated Voltage Mounting Panel Cutout